Electrical Test Program - Test (Retractable Trunk Lid Grip)

Test step
DTC
Test scope
Test connection
Test condition
Nominal value
Possible cause/Remedy
1.0 Rotary tumbler/trunk lid
switch (S88/1)
Voltage supply

 

21

A37

 

18

Disconnect right and left tail lamp connectors.
Trunk lid:
closed



>5 V



Wiring,
1.1,
PSE control module (A37 or A37/1).
   


open <1 V Wiring,
1.1,
A37 or A37/1.
1.1 S88/1
Resistance

 

21

A37

 

18

Disconnect PSE control module (A37 or A37/1)
from
Trunk lid:
closed


open




>20 k


<40




Wiring,
S88/1.

Wiring,
S88/1.