Diagnostic Manual, Body and Accessories,
Volume 1.1
Pneumatic Test Program - Test (RTR)
Preliminary work:
Diagnostic Trouble Code (DTC) Memory
12 PSE |
Data (mbar)
Test procedure |
Permissible deviation |
Allowable system leakage of 300 mbar
vacuum in 1 minute. |
30
mbar |
Allowable leakage of actuators with
line at 300 mbar vacuum in 1 minute. |
25
mbar |
|
Preparation for Test:
As of model year 1995:
1. Disconnect pneumatic line connected to connector F of pneumatic
distributor.
2. Connect tester to disconnected pneumatic line using rubber hose, part
no. 007 997 61 82.
3. Remove trim on right side of trunk.
4. Apply battery voltage to electrical connector of RTR control
valve (Y65/3).
If an actuator does not operate correctly and no leakage is found, check
the respective lines for kinks or blockages.
After testing, reconnect prior disconnected pneumatic line using rubber
hose part no. 007 997 61 82 to pneumatic distributor.
Parts Required for Test:
2 Rubber hose, 50 mm long 007 997 61 82
1 Pneumatic line, 1 m long 000 158 14 35
Parts Required for Repair
Rubber hose (as necessary) 007 997 61 82
Note:
The connections on the PSE control module and pneumatic multiple connector
are marked with their German acronyms. In other words:
ZV (German) = CL (English),
SRU (German) = MVA (English),
OSL (German) = OSB (English). |
|
Test scope |
Test connection |
Test condition |
Nominal value |
Possible cause/Remedy |
1.0 |
Pneumatic lines with filler flap
actuator, RTR control valve (Y65/3) (CL), remote trunk lid release actuator
pressurized |
Yellow connector on tester
to connector
|
Apply 600 mbar pressure to entire
system. |
Pressure loss
25 mbar in
1 minute. |
2.0,
3.0,
32 PSE/CL 5.0,
32 PSE/CL 7.0 |
Preparation for Test:
1. Remove trim on right side of trunk.
2. Disconnect pneumatic line from filler flap at RTR control valve (Y65/3).
3. Connect tester at disconnected pneumatic line at RTR control
valve (Y65/3).
4. Disconnect electrical connector at RTR control valve (Y65/3).
Parts Required for Test:
1 Pneumatic line, 1 m long 000 158 14 35
2 Rubber hose, 50 mm long 007 997 61 82
|
|
Test scope |
Test connection |
Test condition |
Nominal value |
Possible cause/Remedy |
2.0 |
RTR control valve
valve (Y65/3) (CL) |
Yellow connector
on tester. |
Apply 600 mbar pressure to RTR control
valve (Y65/3).
|
Pressure loss
25 mbar in
1 minute.
|
RTR control valve leaks.
Replace. |
Preparation for Test:
1. Remove RTR pneumatic actuator.
2. Connect tester to RTR actuator using connector 202 805 03 44.
Parts Required for Test:
1 Connector 202 805 03 44
1 Pneumatic line, 1m long 000 158 14 35
2 Connector, 50 mm long 007 997 61 82
|
|
Test scope |
Test connection |
Test condition |
Nominal value |
Possible cause/Remedy |
3.0 |
RTR pneumatic actuator
pressurized |
Yellow connector
on tester. |
Apply 600 mbar pressure
to RTR actuator. |
Pressure loss
25 mbar in
1 minute.
|
RTR actuator leaks.
Replace. |
|