Home
Diagnostic Manual, Body and Accessories,
Volume 1.1

 Printable version
LOCATION:    3.1 Model 140  Pneumatic System Equipment (PSE) >   33 Pneumatic Test Program - Pneumatic Multiple Connector Test (PSE)


Pneumatic Test Program - Pneumatic Multiple Connector Test (PSE)

Note:
The pneumatic multiple connector was eliminated as of 08/94.

Preparation for Test:
1. Pry off all pneumatic lines from pneumatic multiple connector (using a 7 mm open end wrench).
2. Plug all connections on the upper side of the pneumatic multiple connector with plugs (part no. 124 805 02 44).
3. Connect vacuum/pressure tester to the bottom side of the pneumatic multiple connector to test the individual connections
ZV, RH, FKS, SFG, PU, PÜ

Parts Required for Test:
15 Plugs 124 805 02 44
1 Connector 129 805 04 44

Note:
The connections on the PSE control module and pneumatic multiple connector are marked with their German acronyms. In other words:
ZV (German) = CL (English),
RH (German) = BA (English),
FKS (German) = RHR (English),
SFG (German) = RTG (English),
PÜ/P+ (OSL) (German) = PÜ/P+ (OSB) (English),
PU/P- (SRU) (German) = PU/P- (MVA) (English).

Test scope Test connection Test condition Nominal value Possible cause/Remedy
1.0 Pressure leakage Yellow connector on tester to connections ZV, RH, SFG, or P+ on the bottom of the connector.
Apply 600 mbar pressure to connector. Pressure drop
of 5 mbar
in 1 minute.
Pneumatic multiple connector.
2.0 Vacuum leakage Black connector on tester to connections ZV, RH, SFG, FKS on the bottom
of the connector.
Apply 300 mbar vacuum
to connector.
Vacuum loss
of 5 mbar
in 1 minute.
Pneumatic multiple connector.