Diagnostic Manual, Body and Accessories,
Volume 1.1
Pneumatic Test Program - Test (RTR)
Data (mbar)
Test procedure |
Permissible deviation |
Allowable system leakage of 300 mbar vacuum in 1 minute. |
30 mbar |
Allowable leakage of actuators with line at 300 mbar vacuum in 1 minute. |
25 mbar |
Preparation for Test:
1. Disconnect yellow central locking (CL) pneumatic
line from PSE control
module.
2. Connect tester to disconnected pneumatic line using
connector 202 805 03 44.
3. Remove trunk lid lock, do not disconnect pneumatic line.
4. Apply battery voltage to electrical connector of RTR control
valve (Y65/3).
If an actuator does not operate correctly and no leakage is found, check
the respective lines for kinks or blockages.
Parts Required for Test:
1 Connector 202 805 03 44
2 Rubber hose, 50 mm long 007 997 61 82
1 Pneumatic line, 1 m long 000 158 14 35
Note:
The connections on the PSE control module and pneumatic multiple connector
are marked with their German acronyms. In other words:
ZV (German) = CL (English),
SRU (German) = MVA (English),
OSL (German) = OSB (English).
|
|
|
Test scope |
Test connection |
Test condition |
Nominal value |
Possible cause/Remedy |
1.0 |
|
Entire system pressurized |
Yellow connector on tester to connector
|
Apply 600 mbar pressure to entire system. |
Pressure loss 30 mbar in 1 minute. |
2.0,
3.0. |
Preparation for Test:
1. Disconnect pneumatic line connected to connector F of pneumatic
distributor.
2. Connect tester to disconnected pneumatic line using rubber hose, part
no. 007 997 61 82.
3. Remove trunk lid lock, do not disconnect pneumatic line.
4. Apply battery voltage to RTR control valve (Y65/3).
After testing, reconnect prior disconnected pneumatic line using rubber
hose part no. 007 997 61 82 to pneumatic distributor.
Parts Required for Test:
1 Rubber hose, 50 mm long 007 997 61 82
Parts Required for Repair:
Rubber hose (as necessary) 007 997 61 82
|
|
|
Test scope |
Test connection |
Test condition |
Nominal value |
Possible cause/Remedy |
2.0 |
|
Actuators with pneumatic lines and RTR control valve (Y65/3) pressurized |
Yellow connector
on tester. |
Apply 600 mbar pressure to pneumatic lines and RTR control valve (Y65/3).
|
Pressure loss
25 mbar in 1 minute.
|
3.0,
32 PSE/CL 7.0 |
Preparation for Test:
1. Remove trunk lid lock.
2. Connect tester to pneumatic connector of RTR control valve (Y65/3).
3. Apply battery voltage to electrical connector of RTR control
valve (Y65/3).
Parts Required for Test:
1 Pneumatic line, 1m long 000 158 14 35
2 Connector, 50 mm long 007 997 61 82
|
|
|
Test scope |
Test connection |
Test condition |
Nominal value |
Possible cause/Remedy |
3.0 |
|
RTR control valve (Y65/3) with RTR pneumatic actuator pressurized |
Yellow connector
on tester. |
Apply 600 mbar pressure
to actuator and pneumatic line. |
Pressure loss
25 mbar in 1 minute.
|
RTR control valve with actuator leaks.
Replace. |
|