Diagnostic Manual, Body and Accessories,
Volume 1.1
Pneumatic Test Program - Pneumatic Multiple Connector Test (PSE)
Note:
The multiple connector was eliminated as of approx. 12/93
Preparation for Test:
1. Pry off all pneumatic lines from pneumatic multiple connector (using
a 7 mm open end wrench.)
2. Plug all connections on the upper side of the pneumatic multiple connector
with plugs (part no. 124 805 02 44).
3. Connect vacuum/pressure tester to the bottom side of the pneumatic multiple
connector to test the individual connections ZV, SRU, OSL.
Parts Required for Test:
10 Plugs 124 805 02 44
1 Connector 129 805 04 44
Notes:
The connections on the PSE control module and pneumatic multiple connector
are marked with their German acronyms. In other words:
ZV (German) = CL (English),
SRU (German) = MVA (English),
OSL (German) = OSB (English). |
|
|
Test scope |
Test connection |
Test condition |
Nominal value |
Possible cause/Remedy |
1.0 |
Pressure leakage |
Yellow connector on tester
to connections ZV, OSL, on the bottom of the connector.
|
Apply 600 mbar pressure to multiple
connector. |
Pressure drop
of 5 mbar
in 1 minute. |
Pneumatic multiple connector. |
2.0 |
Vacuum leakage |
Black connector on tester
to connections ZV, SRU, on the bottom of the connector.
|
Apply 300 mbar vacuum to multiple
connector. |
Vacuum loss
of 5 mbar
in 1 minute. |
Pneumatic multiple connector. |
|