Home
Diagnostic Manual, Body and Accessories,
Volume 1.1

 Printable version
LOCATION:    3.2 Model 202  Pneumatic System Equipment (PSE) >   32 Pneumatic Test Program - Pneumatic Multiple Connector Test (PSE)


Pneumatic Test Program - Pneumatic Multiple Connector Test (PSE)

Note:
The multiple connector was eliminated as of approx. 12/93

Preparation for Test:
1. Pry off all pneumatic lines from pneumatic multiple connector (using a 7 mm open end wrench.)
2. Plug all connections on the upper side of the pneumatic multiple connector with plugs (part no. 124 805 02 44).
3. Connect vacuum/pressure tester to the bottom side of the pneumatic multiple connector to test the individual connections ZV, SRU, OSL.

Parts Required for Test:
10 Plugs 124 805 02 44
1 Connector 129 805 04 44

Notes:
The connections on the PSE control module and pneumatic multiple connector are marked with their German acronyms. In other words:
ZV (German) = CL (English),
SRU (German) = MVA (English),
OSL (German) = OSB (English).

Test scope Test connection Test condition Nominal value Possible cause/Remedy
1.0 Pressure leakage Yellow connector on tester to connections ZV, OSL, on the bottom of the connector.
Apply 600 mbar pressure to multiple connector. Pressure drop
of 5 mbar
in 1 minute.
Pneumatic multiple connector.
2.0 Vacuum leakage Black connector on tester to connections ZV, SRU, on the bottom of the connector.
Apply 300 mbar vacuum to multiple connector. Vacuum loss
of 5 mbar
in 1 minute.
Pneumatic multiple connector.