LOCATION:    3.3 Models 170, 210   Pneumatic System Equipment (PSE) >   32 Pneumatic Test Program - Test (RHR)


Pneumatic Test Program - Test (RHR)

Preliminary work:
PSE control module voltage supply 23 PSE 1.0, 2.0
PSE Control Module Test 32 PSE

Data (mbar)

Test procedure Permissible deviation
Allowable system leakage of 300 mbar vacuum in 1 minute. 30 mbar
Allowable leakage of actuators with line at 300 mbar vacuum in 1 minute. 25 mbar

Preparation for Test:
1. Provide access to PSE control module (A37), disconnect white RHR pneumatic line with socket from PSE control module.
2. Connect tester to disconnected socket using connector 202 805 03 44.


If an actuator does not operate correctly and no leakage is found, check the respective lines for kinks or blockages.

Parts Required for Test:
1 Connector 202 805 03 44
2 Rubber hose, 50 mm long 007 997 61 82
1 Pneumatic line, 1 m long 000 158 14 35

Note:
The connections on the PSE control module and pneumatic multiple connector are marked with their German acronyms. In other words:
ZV (German) = CL (English),
SRU (German) = MVA (English),
OSL (German) = OSB (English).

Test scope Test connection Test condition Nominal value Possible cause/Remedy
1.0 Complete system evacuated Black connector on tester to connector

Apply 300 mbar vacuum to entire system. Vacuum loss
30 mbar in
1 minute.
2.0,
3.0

Preparation for Test:
1. Remove RHR actuators.
2. Connect tester to pneumatic connection of actuator.

Parts Required for Test:
2 Rubber hose, 50 mm long 007 997 61 82
1 Pneumatic line, 1m long 000 158 14 35
1 Socket 202 800 02 53

Test scope Test connection Test condition Nominal value Possible cause/Remedy
2.0 Actuator hold vacuum Black connector
on tester.
Apply 300 mbar vacuum to actuator. Vacuum loss
25 mbar in
1 minute.
Actuator leaks.
Replace.

Preparation for Test:
1. Connect tester to one end of pneumatic line and plug other end with cap, part no. 124 805 02 44.

Parts Required for Test:
1 Connector 202 805 03 44
3 Cap 124 805 02 44
1 Connector, 50 mm long 007 997 61 82

Test scope Test connection Test condition Nominal value Possible cause/Remedy
3.0 Vacuum leakage Black connector
on tester.
Apply 300 mbar vacuum
to pneumatic line.
Vacuum loss
0 mbar in
1 minute.
Pneumatic line leaks.
Replace.