Home
Diagnostic Manual, Body and Accessories,
Volume 1.1

 Printable version
LOCATION:    3.3 Models 170, 210   Pneumatic System Equipment (PSE) >   23 Electrical Test Program - Test


Electrical Test Program - Test

Test scope Test connection Test condition Nominal value Possible cause/Remedy
1.0 Remote trunk release



 

 

 



 

 

Trunk lid closed.
Trunk lid not locked with mechanical key.
Remote trunk release switch (S15):
Press switch:





Trunk lid opens.
Wiring,
1.1,
2.0,
23 PSE 1.0-8.0,
3.1 23 1.0-3.0,
32 1.0,
32 PSE 2.0,
Combination control
module (N10-1),
PSE control module (A37).
1.1   Remote trunk release
switch (S15)






N10-1

19
(A)














A37

3
(2)
Disconnect combination control module (N10-1) from .

S15:
Rest position

S15:
Hold pressed







>20 k


< 1
Wiring,
S15
2.0   Activate RTR control
valve (Y65/3) (CL)

A37
3
(2)


A37

7
(1)
Remote trunk release switch (S15):
Rest position

S15:
Hold pressed



< 1 V


11 - 14 V, as long as PSE pump runs, (use fluke 83, 88 to measure voltage).
Wiring,
1.1,
23 PSE 1.0-8.0,
3.1 23 1.0-3.0,
PSE control module (A37).