Test scope |
Test
connection
|
Test condition |
Nominal value |
Possible cause/Remedy |
1.0 |
PSE control module (A37)
Voltage supply
Circuit 30, 31
Model 140
Model 129
Model 170 |
21
2
(1)
3
(2) |
|
|
Disconnect connector 1 on A37
Disconnect connector 2 on A37
|
11 - 14 V |
Circuit 31,
1.1 |
1.1 |
Circuit 30
Model 140
Model 129
Model 170 |
|
|
A37
7
A37
1
(1)
A37
2
(2)
|
Disconnect connector 1 on
A37
Disconnect connector 2 on
A37
|
|
Circuit 31 |
2.0 |
PSE control module (A37)
Voltage supply
Circuit 15, 31
Model 140
Model 129
|
21
2
(1)
|
|
|
Ignition: ON
Ignition: OFF
Model 129 only:
Disconnect connector 1
from A37
|
11 - 14 V
>1 V |
Circuit 31,
2.1 |
2.1 |
Circuit 15
Model 140
Model 129 |
|
|
|
Ignition: ON
Ignition: OFF
|
11 - 14 V
>1 V
|
Circuit 15 |
3.0 |
Left front door switch
(S17/3) and right front door
switch (S17/4)
Model 140
Model 129
|
3
A37
62
(2.16) |
|
7
|
Both front doors closed.
Left door open.
Left and right door closed.
Right door open. |
>1 V
11 - 14 V
>1 V
11 - 14 V |
Wiring,
S17/3,
S17/4 |
4.0 |
Left front door
switch (S17/3)
Model 170 |
A37
60
(1.14) |
|
|
Left front door closed.
Left front door open.
|
>1 V
11 - 14 V |
Wiring,
S17/3 |
5.0 |
Right front door
switch (S17/4)
Model 170 |
A37
62
(1.16) |
|
|
Right front door closed.
Right front door open.
|
>1 V
11 - 14 V |
Wiring,
S17/4 |
6.0 |
Left rear door switch
(S17/5) and right rear door
switch (S17/6)
Model 140 only |
19 |
A37
|
7
|
Both rear doors closed.
Left rear door open.
Both rear doors closed.
Right rear door open. |
>1 V
11 - 14 V
>1 V
11 - 14 V
|
Wiring,
S17/5,
S17/6 |
7.0 |
Rotary tumbler/trunk lid
microswitch (S88/1)
Model 140
Model 129 |
18
A37
61
(2.15)
|
|
7
|
Trunk lid closed closed.
Trunk lid open. |
>1 V
11 - 14 V
|
Wiring,
S88/1 |
8.0 |
Retractable hardtop closed
limit switch (S69/1)
(right pin)
Model 170 |
A37
59
(1.13) |
|
|
Trunk lid closed.
Trunk lid open. |
<1 V
11 - 14 V |
Wiring,
S69/1 |
9.0 |
CAN data line L,
PSE control module (A37),
Combination control
module (N10-3)
-//-
Model 170 only,
Socket 9, Socket 62
|
A37
9
(1) |
|
N10-3
62
(A)
|
Disconnect A37 from ,
Disconnect N10-3 from . |
<1
|
Wiring. |
10.0 |
CAN data line H,
PSE control module (A37),
Combination control
module (N10-3)
-//-
Model 170 only,
Socket 10, Socket 78
|
A37
10
(1) |
|
N10-3
78
(A)
|
Disconnect A37 from ,
Disconnect N10-3 from . |
<1 |
Wiring. |
11.0 |
CAN data line L,
PSE control module (A37),
Combination control
module (N10-3)
+
Model 170 only,
Socket 9, Socket 1
|
A37
9
(1) |
|
A37
1
(2)
|
Disconnect A37 from ,
Disconnect battery ground
cable.
Disconnect N10-3 |
>20 k |
Wiring. |
12.0 |
CAN data line H,
PSE control module (A37),
Combination control
module (N10-3)
+
Model 170 only,
Socket 10, Socket 1
|
A37
10
(1) |
|
A37
1
(2)
|
Disconnect A37 from ,
Disconnect battery ground
cable.
Disconnect combination control module (N10-3). |
>20 k
|
Wiring. |
13.0 |
CAN data line L,
PSE control module (A37),
Combination control
module (N10-3)
-
Model 170 only,
Socket 3, Socket 9
|
A37
3
(2) |
|
A37
9
(1)
|
Disconnect A37 from ,
Disconnect N10-3 |
>20 k |
Wiring. |
14.0 |
CAN data line H,
PSE control module (A37),
Combination control
module (N10-3)
-
Model 170 only,
Socket 3, Socket 10
|
A37
3
(2) |
|
A37
10
(1)
|
Disconnect A37 from ,
Disconnect N10-3 |
>20 k |
Wiring. |
15.0 |
Data line, CAN L / CAN
H,
PSE control module (A37),
Combination control
module (N10-3)
-
to each other
Model 170 only,
Socket 9, Socket 10
|
9
(1) |
A37
|
10
(1)
|
Disconnect A37 from ,
Disconnect N10-3 |
>20 k
|
Wiring. |