STI Home
Diagnostic Manual, Body and Accessories,
Volume 2.1

 Printable version
LOCATION:    7.1 Networked Systems (NS) (CAN)  >   22 Electrical Test Program - Preparation for Test


Electrical Test Program - Preparation for Test

Preparation for Test:
1. Battery voltage > 11 V,
2. Fuses ok,
3. Disconnect the battery negative cable prior to disconnecting or connecting any of the connectors of the control modules, otherwise fault codes may be stored in error in the memory.
4. CAN data lines are ok, see 23



For test measuring purposes, the CAN connection to the following control modules must be connected:
PSE control module (A37)
Signal pickup-and activation module (SAM) (N10/1)

Electrical Wiring Diagrams:
See Electric Troubleshooting Manual: Model 202, Groups 00, 54, 67, 82
Model 208, Groups 00, 54, 67, 82
Model 210, Groups 00, 54, 67, 82

Conventional tools, test equipment

Description Brand, model, etc.
Multimeter 1) Fluke models 23, 83, 85, 87
1) Available through the MBUSA Standard Equipment Program.