Diagnostic Manual, Body and Accessories,
Volume 2.1
Electrical Test Program - Preparation for Test
Preparation for Test:
1. Battery voltage > 11 V,
2. Fuses ok,
3. Disconnect the battery negative cable prior to disconnecting or connecting
any of the connectors of the control modules, otherwise fault codes may
be stored in error in the memory.
4. CAN data lines are ok, see 23
For test measuring purposes, the CAN connection to the following control
modules must be connected:
PSE control module (A37)
Signal pickup-and activation module (SAM) (N10/1)
Electrical Wiring Diagrams:
See Electric Troubleshooting Manual: Model 202, Groups 00, 54, 67, 82
Model 208, Groups 00, 54, 67, 82
Model 210, Groups 00, 54, 67, 82 |
Conventional tools, test equipment
Description |
Brand, model, etc. |
Multimeter 1) |
Fluke models 23, 83, 85, 87 |
1) Available through the
MBUSA Standard Equipment Program. |
|