| Test step
 | DTC
 | Scope of test | Test connection | Test condition | Nominal value | Possible cause/Remedy | 
  
    | 1.0 |  | Power soft top control module
      (N52) Voltage supply
 Circuits 30, 15
 | 
 11
  | N52  
        X     | 
        
          12 |  | 
 11 - 14 V
 |  1.1, Circuit 31.
 | 
  
    |  |  |  | 
 6
  | N52  
        Z     | 
        
          5 | 
 Ignition: ON
 | 
 11 - 14 V
 |  | 
  
    | 1.1 |  | Voltage supply Circuits 30, 15
 | 
 
  | N52  
        X     | 
        
          12 |  | 
 11 - 14 V
 | 
 Circuit 30.
 | 
  
    |  |  |  | 
 
  | N52  
        Z     | 
        
          5 | 
 Ignition: ON
 | 
 11 - 14 V
 | 
 Circuit 15.
 | 
  
    | 2.0 |   | CST/RB hydraulic unit (A7/5) switching
      circuit Voltage supply
 | 1
  | A7/5x1   | 
          4 | Disconnect connector (A7/5x1).
 | 11 - 14 V
 | Wiring. | 
  
    |  |  |  | 5
  | A7/5x1   | 
          4 |  | 11 - 14 V
 
 |  | 
  
    | [2.0] |  |  | 
 11
  | N52  
        X     | 
        
          12 | Ignition: ON 
 Open front locks.
 Press power soft top switch (S84) in opening or closing position.
 | 0 - 1 V 
 
 
 11 - 14 V
 
 
 Hydraulic unit (A7/5m1) runs.
 
 
 |  18.0, 
 
 
 
  18.0, 
  21.0, 
 
  2.1, Relay (A7/5k1),
 Wiring.
 | 
  
    | 2.1 |  | A7/5m1 | 
 
 | 
 
 | 
 
 | Unplug A7/5k1. Bridge sockets 1 and 3 of A7/5k1 connector.
 
 
 | A7/5m1 runs
 
 | Wiring,
 A7/5m1.
 
 | 
  
    | 3.0 |  | Operating time exceeded | 
 
 | 
 
 | 
 
 | Erase DTC's. | DTC   
 
 | Control module (N52). 
 
 | 
  
    | 4.0 |  | Limit switch signals illogical | 
 
 | 
 
 | 
 
 | Check limit switch signals according
      to chart (  24). 
 | 
 
 | Wiring, Limit switch.
 | 
  
            | 5.0 |  | Soft top compartment cover "locked"
      switch (A25/1s2) circuit Voltage supply
 | 
 
  |  | N52  
        Y      14 | Control module (N52) in diagnostic
      mode  22. Soft top compartment cover:
 locked
 | 
 
 
 0 - 1 V
 | 
 
 
 
  5.1, | 
  
    |  |  |  | 
 
 | 
 
 | 
 
 | unlocked 
 
 | 11 - 14 V 
 
 |  5.1, | 
  
            | 5.1 |  | A25/1s2 Resistance
 | 
 
  |  | N52  
        Y     
        14 | Ignition: OFF Disconnect test cable (Y) from control module (N52).
 Soft top compartment cover:
 locked
 | 
 
 
 
 0 - 5
  | A25/1s2, Wiring,
 If nominal value is obtained: N52.
 
 
 | 
  
    |  |  |  | 
 
 |  | 
 
 | unlocked 
 
 | >20 k   
 
 | 
 
 | 
  
            | 6.0 |  | Soft top compartment cover "closed"
      switch (A25/1s1) circuit Voltage supply
 | 
 
  |  | N52  
        Y     
        13 | Control module (N52) in diagnostic
      mode  22. Soft top compartment cover:
 closed
 | 
 
 
 0 - 1 V
 | 
 
 
 
  6.1, | 
  
    |  |  |  | 
 
 | 
 
 |  | opened | 11 - 14 V |  6.1, | 
  
    | 6.1 |  | A25/1s1 Resistance
 | 
 
  |  | N52 Y      13 | Ignition: OFF Disconnect test cable (Y) from control module (N52).
 Soft top compartment cover:
 closed
 | 
 
 
 
 0 - 5
  | A25/1s1, Wiring,
 If nominal value is obtained: N52.
 | 
  
    |  |  |  | 
 | 
 | 
 | opened | >20 k  |  | 
  
            | 7.0 |  | Soft top compartment cover "open"
      switch (S84/5) circuit Voltage supply
 | 
 
  |  | N52 Y      15 | Control module (N52) in diagnostic
      mode  22. Soft top compartment cover:
 opened
 | 
 
 
 0 - 1 V
 | 
 
 
 
  7.1, | 
  
    |  |  |  |  |  |  | closed 
 | 11 - 14 V |  7.1, | 
  
    | 7.1 |  | S84/5 Resistance
 | 
 
  |  | N52 Y      15 | Ignition: OFF Disconnect test cable (Y) from control module (N52).
 Soft top compartment cover:
 
 opened
 | 
 
 
 
 
 0 - 5
  | S84/5, Wiring,
 If nominal value is obtained: N52.
 | 
  
    |  |  |  |  |  | 
 | closed | >20 k   
 
 |  | 
  
    | 8.0 |  | Soft top fabric bow "locked" switch
      (S84/8) circuit Voltage supply
 | 
 
  |  | N52  
        Y      11 | Control module (N52) in diagnostic
      mode  22. Fabric bow:
 locked
 | 
 
 0 - 1 V
 | 
 
 
  8.1, 
 | 
  
    |  |  |  | 
 |  |  | unlocked | 11 - 14 V |  8.1. | 
  
    | 8.1 |  | S84/8 Resistance
 | 
 
  |  | N52  
        Y      11 
       | Ignition: OFF Disconnect test cable (Y) from control module (N52).
 Fabric bow:
 locked
 | 
 
 
 0 - 5
   
 | S84/8, Wiring,
 If nominal value is obtained: N52.
 
 
 | 
  
    |  |  |  |  |  |  | unlocked | >20 k  | 
 | 
  
    | 9.0 |  | Soft top fabric bow "down" switch
      (S84/7) circuit Voltage supply
 | 
 
  |  | N52  
        Y      10 | Control module (N52) in diagnostic
      mode  22. Fabric bow:
 lowered
 | 
 
 0 - 1 V
 | 
 
 
  9.1, 
 | 
  
    |  |  |  | 
 |  |  | raised | 11 - 14 V 
 
 |  9.1, N52.
 | 
  
    | 9.1 |  | S84/7 Resistance
 | 
 
  |  | N52  
        Y      10 | Ignition: OFF Disconnect test cable (Y) from control module (N52).
 Fabric bow:
 owered
 | 
 
 
 0 - 5
  | S84/7, Wiring,
 If nominal value is obtained: N52.
 | 
  
    |  |  |  | 
 
 |  | 
 
 | raised 
 
 | >20 k   
 
 |  | 
  
    | 10.0 |   | Soft top fabric bow "raised" switch
      (S84/6) circuit Voltage supply
 | 
 
  |  | N52  
        Y      12 | Control module (N52) in diagnostic
      mode  22. Fabric bow:
 raised
 | 
 
 0 - 1 V
 | 
 
 
  10.1, | 
  
    |  |  |  | 
 
 |  | 
 
 | lowered 
 
 | 11 - 14 V 
 
 |  10.1, 
 
 | 
  
    | 10.1 |   | S84/6 Resistance
 | 
 
  |  | N52  
        Y      12 | Ignition: OFF Disconnect test cable (Y) from control module (N52).
 Fabric bow:
 raised
 | 
 
 
 0 - 5
  | S84/6, Wiring,
 If nominal value is obtained: N52.
 | 
  
    |  |  |  | 
 |  | 
 | lowered | >20 k   
 
 |  | 
  
    | 11.0 |   | Left front soft top "locked" switch
      (S84/1) circuit Voltage supply
 | 
 
  |  | N52  
        Y      5 | Control module (N52) in diagnostic
      mode  22. Front of soft top:
 locked
 | 
 
 0 - 1 V
 | 
 
 
  11.1, | 
  
    |  |  |  | 
 |  |  | unlocked | 11 - 14 V |  11.1, | 
  
    | 11.1 |   | S84/1 Resistance
 | 
 
  |  | N52  
        Y      5 | Ignition: OFF Disconnect test cable (Y) from control module (N52).
 Front of soft top:
 locked
 | 
 
 
 0 - 5
  | S84/1, Wiring,
 If nominal value is obtained: N52.
 
 
 | 
  
    |  |  |  |  |  |  | unlocked | >20 k  | 
 | 
  
    | 12.0 |   | Right front soft top "locked"
      switch (S84/2) circuit Voltage supply
 | 
 
  |  | N52  
        Y      6 | Control module (N52) in diagnostic
      mode  22. Front of soft top:
 locked
 | 
 
 0 - 1 V
 | 
 
 
  12.1, | 
  
    |  |  |  |  |  | 
 | unlocked | 11 - 14 V 
 
 |  12.1, | 
  
            | 12.1  |   | S84/2 Resistance
 | 
 
  |  | N52  
        Y      6 | Ignition: OFF Disconnect test cable (Y) from control module (N52).
 Front of soft top:
 locked
 | 
 
 
 0 - 5
  | S84/2, Wiring,
 If nominal value is obtained: N52.
 | 
  
    |  |  |  | 
 
 |  | 
 | unlocked 
 
 | >20 k   
 
 |  | 
  
    | 13.0 |   | Soft top "open" switch (soft top
      in storage compartment) (S84/3) circuit Voltage supply
 | 
 
  |  | N52  
        Y      9 | Control module in diagnostic mode  22 Soft top:
 opened
 | 
 
 0 - 1 V
 | 
 
 
  13.1, | 
  
    |  |  |  | 
 
 |  | 
 | closed 
 
 | 11 - 14 V 
 
 |  13.1. 
 
 | 
  
    | 13.1 |   | S84/3 Resistance
 | 
 
  |  | N52  
        Y      9 | Ignition: OFF Disconnect test cable (Y) from control module (N52)
 Soft top:
 opened
 | 
 
 
 0 - 5
  | S84/3, Wiring,
 If nominal value is obtained: N52.
 | 
  
    |  |  |  | 
 |  | 
 | closed | >20 k   
 
 |  | 
  
    | 14.0 |   | Soft top "overhead" switch (S84/4)
      circuit Voltage supply
 | 
 
  |  | N52  
        Y      7 | Control module (N52) in diagnostic
      mode  22. Soft top:
 closed
 | 
 
 0 - 1 V
 | 
 
 
  14.1, | 
  
    |  |  |  | 
 
 |  | 
 
 | opened 
 
 | 11 - 14 V 
 
 |  14.1. | 
  
    | 14.1 |   | S84/4 Resistance
 | 
 
  |  | N52  
        Y      7 
        
       | Ignition: OFF Disconnect test cable (Y) from control module (N52).
 Soft top:
 closed
 | 
 
 
 0 - 5
  | S84/4, Wiring,
 If nominal value is obtained: N52.
 
 
 | 
  
    |  |  |  | 
 
 |  | 
 
 | opened 
 
 | >20 k   
 
 | 
 
 | 
  
    | 15.0 |   | RB "retracted" switch (S83/5)
      circuit Voltage supply
 | 
 |  | N52  
        Y      16 
       | Control module (N52) in diagnostic
      mode  22. Roll bar:
 retracted
 | 
 
 0 - 1 V
 | 
 
 
  15.1, | 
  
    |  |  |  | 
 |  | 
 | extended | 11 - 14 V 
 
 |  15.1. | 
  
    | 15.1 |   | S83/5 Resistance
 | 
 
  |  | N52  
        Y      16 | Ignition: OFF Disconnect test cable (Y) from control module (N52).
 Roll bar:
 retracted
 | 
 
 
 0 - 5
  | S83/5, Wiring,
 If nominal value is obtained: N52.
 | 
  
    |  |  |  | 
 
 |  | 
 
 | extended 
 
 | >20 k   
 |  | 
  
    | 16.0 |   | RB "extended" switch (S83/6) circuit Voltage supply
 | 
 
  |  | N52  
        Y      17 | Control module (N52) in diagnostic
      mode  22. Roll bar:
 extended
 | 
 
 0 - 1 V
 | 
 
 
  16.1, | 
  
    |  |  |  | 
 
 |  | 
 
 | retracted 
 
 | 11 - 14 V 
 
 |  16.1. 
 
 | 
  
    | 16.1 |   | S83/6 Resistance
 | 
  |  | N52  
        Y      17 | Ignition: OFF Disconnect test cable (Y) from control module (N52).
 Roll bar:
 extended
 | 
 
 
 0 - 5
  | S83/6, Wiring,
 If nominal value is obtained: N52.
 | 
  
    |  |  |  | 
 |  | 
 | retracted | >20 k   
 
 |  | 
  
    | 17.0 |   | Roll bar Crash deployment
 | 
 
 |  | 
 
 | Ignition: OFF, ON Press RB switch (S83) to extend position,
 (approx. 10 sec.).
 | 
 
 | Crash deployment occurred. | 
  
    |  |  |  | 
 
 |  | 
 
 | Retract roll bar using RB
 switch (S83).
 
 | Roll bar is retracted.
 
 |  | 
  
    | 18.0 |   | Power soft top switch (S84) circuit Voltage supply
 | 
 
  |  | N52  
        Y      1 | Ignition: ON 
 
 Press switch S84 to closing position.
 | 11 - 14 V 
 
 0 - 1 V
 
 
 |  18.1. 
 
 | 
  
    |  |  |  | 
 
  |  | N52  
        Y      2 | Ignition: ON 
 
 Press switch S84 to opening position.
 
 
 | 11 - 14 V 
 
 0 - 1 V
 
 
 | 
 
 | 
  
    | 18.1 |   | S84 Resistance
 | 
 
  |  | N52  
        Y      1 | Disconnect test cable (Y) from control
      module (N52) Switch S84 in:
 | 
 
 | Wiring, S84,
 If nominal value is obtained: N52.
 | 
  
    |  |  |  | 
 
  |  | N52  
        Y      2 | rest position 
 closing position
 
 rest position
 
 opening position
 
 | >20 k  
 0 - 5
  
 
 >20 k
  
 0 - 5
   
 |  | 
  
    | 19.0 |   | Vehicle speed signal | 
 
  |  | N52  
        Y      35 | Drive vehicle at approx. 25 mph (40
      km/h) | 
 
 | 
 
 | 
  
    | 20.0 |  | RB switch (S83) circuit and RB
      switch (rear center console) (S83/4) circuit Voltage supply
 | 
 
  |  | N52  
        Y      5 | Ignition: ON Rear power window safety switch (S21/7) in unlocked position.
 S83 and S83/4 in:
 rest position
 | 
 
 
 
 11 - 14 V
 | 
 
 
 
 
  20.1, 
  20.2. | 
  
    | [20.0] |  |  | 
 
 |  | 
 
 | Push switch S83 to extend roll
      bar. 
 Push switch S83/4 to extend roll bar.
 | 0 - 1 V 
 
 0 - 1 V
 
 
 |  20.1, 
 
 
  20.2, 
  22.0, 
 
 | 
  
    |  |  |  | 
 
  |  | N52  
        X      4 | S83 and S83/4 in: rest position
 
 
 Push switch S83 to retract roll bar.
 
 Push switch S83/4 to retract roll bar.
 
 | 
 11 - 14 V
 
 
 0 - 1 V
 
 
 
 0 - 1 V
 
 | 
  20.1, 
  20.2, 
 
  20.1, 
 
 
  20.2, 
  22.0. 
 
 
 | 
  
    | 20.1 |  | S83 Resistance
 | 
 
  |  | N52  
        X      3 
       | Ignition: OFF Disconnect test cable (Y) from control module.
 S83 and S83/4 in:
 rest position
 
 Push switch S83 to extend roll bar.
 | 
 
 
 
 
 
 >20 k
   
 0 - 5
  | Wiring, S83,
 S83/4.
 
 
 | 
  
    | [20.1] |  |  | 
 
  |  | N52  
        Y      4 | S83 and S83/4 in: rest position
 
 
 Push switch S83 to retract roll bar.
 
 | 
 >20 k
   
 
 0 - 5
  | Wiring, S83,
 S83/4,
 If nominal value is obtained: control module (N52).
 | 
  
    | 20.2 |  | S83/4 Resistance
 | 
 
  |  | N52  
        Y      3 | Ignition: OFF Disconnect test cable (Y) from N52.
 S83 and S83/4 in:
 rest position
 | 
 
 
 >20 k
  | Wiring, S83,
 S83/4,
 If nominal value is obtained: N52.
 
 
 | 
  
    |  |  |  |  |  |  | Push switch S83/4 to extend
      roll bar. | 0 - 5  |  | 
  
    |  |  |  | 
 
  |  | N52  
        Y      4 | S83 and S83/4 in: rest position
 | >20 k
  |  | 
  
    |  |  |  | 
 |  | 
 | Push switch S83/4 to retract
      roll bar. | 0 - 5   
 |  | 
  
    | 21.0 |   | Rod side valve (Y57y10) circuit Voltage supply
 | 
 11
  | N52  
        X     | 
        
          10 | Ignition: ON Operate roll bar using
 switch (S83) to:
 | 0 - 1 V 
 
 | S83, Control module (N52),
 | 
  
    |  |  |  |  |  |  | retract 
 extend
 
 | 11 - 14 V 
 11 - 14 V
 
 |  21.1, 
 
  21.1. | 
  
    | 21.1 |   | Y57y10 Resistance
 | 
 11
  | N52  
        X     | 
        
          10 | Disconnect test cable (X) from control
      module (N52). | 
 10 - 20
  | Wiring, Y57y10,
 Relay (A7/5k1),
 If nominal value is obtained: N52.
 
 | 
  
    | 22.0 |  | Rear power window safety switch
      (S21/7) circuit Voltage supply
 | 
  |  | N52  
        Y      3 | Ignition: ON Hold switch (S83/4) in roll bar extend position.
 
 Position of S21/7:
 | 
 |  | 
  
    |  |  |  | 
 |  | 
 | locked 
 unlocked
 | 9 - 14 V 
 0 - 1 V
 | Wiring, 
  22.1, 
 Wiring,
 
  22.1, 
  20.0. | 
  
    | 22.1 |  | S21/7 Resistance
 | 
 
  |  | N52  
        X      3 | Ignition: OFF Disconnect test cable (Y) from control module (N52).
 Hold switch S83/4 in roll bar "extend" position.
 Position of S21/7:
 | 
 
 | Wiring, S21/7,
 If nominal value is obtained: N52.
 | 
  
    |  |  |  | 
 
 |  | 
 
 | unlocked 
 locked
 
 | 0 - 5   
 >20 k
  |  | 
  
    | 23.0 |   | Piston side valve (Y57y11) circuit Voltage supply
 | 
 6
  | N52  
        Z     | 
        
          2 | Ignition: ON Operate roll bar using switch (S83) to:
 | 
 
 | 
 
 | 
  
    |  |  |  | 
 
 |  | 
 
 | extend 
 retract
 
 
 | 11 - 14 V 
 0 - 1 V
 |  23.1, 
 Control module (N52).
 
 
 | 
  
    | 23.1 |   | Y57y11 Resistance
 | 
 6
  | N52  
        Z     | 
        
          2 | Disconnect test cable (Z) from control
      module (N52). | 
 5 - 15
  | Wiring, Y57y11,
 If nominal value is obtained: N52.
 | 
  
    | 24.0 |  | Hydraulic unit main valve (A7/5y1)
      1) circuit Voltage supply
 | 
 6
  | N52  
        Z     | 
        
          1 | Ignition: ON 
 Open front locks
 Move soft top switch to closing or opening position roll bar
      retracted.
 | 0 - 1 V 
 10 - 14 V
 
 
 | Control module (N52). 
 
  24.1. | 
  
    | 24.1 |  | A7/5y1 Resistance
 | 
 6
  | N52  
        Z     | 
        
          1 | Disconnect test cable (Z) from control
      module (N52). 
 
 | 5 - 15
   
 | Wiring, A7/5y1,
 If nominal value is obtained: N52.
 | 
  
    | 25.0 |  | Soft top compartment lock valve
      (Y56y3) circuit Voltage supply
 | 
 11
  | N52  
        X     | 
        
          9 | Ignition: ON Operate soft top compartment cover using switch (S84) to:
 | 
 
 | 
 
 | 
  
    |  |  |  | 
 
 |  |  | unlock 
 lock
 
 | 10 - 14 V 
 0 - 1 V
 
 |  25.1. 
 Control module (N52).
 
 | 
  
    | 25.1 |  | Y56y3 Resistance
 | 
 11
  | N52  
        X     | 
        
          9 | Disconnect test cable (X) from control
      module (N52). | 
 5 - 15
  | Wiring, Y56y3,
 If nominal value is obtained: Y56y3 is physically sticking or control module
      (N52).
 | 
  
    | 26.0 |  | Fabric bow lock valve (Y56y4),
      Soft top compartment cover "closed" circuit | 
 11
  | N52  
        X     | 
        
          8 | Ignition: ON Operate fabric bow using power soft top switch (S84) to:
 | 
 
 |  | 
  
    |  |  | Voltage supply | 
 |  | 
 | unlock 
 lock
 | 10 - 14 V 
 0 - 1 V
 |  26.1, 
 Control module (N52).
 | 
  
    | 26.1 |  | Y56y4 Resistance
 | 
 11
  | N52  
        X     | 
        
          8 | Disconnect test cable (X) from control
      module (N52). | 
 5 - 15
  | Wiring, Y56y4,
 If nominal value is obtained: Y56y3 is physically sticking or control module
      (N52).
 | 
  
    | 27.0 |  | Soft top compartment cover drive
      valve (Y56y5), Compartment cover "open" circuit Voltage supply
 | 
 11
  | N52  
        X     | 
        
          5 | Ignition: ON Operate soft top compartment cover using power soft top switch (S84) to:
 | 
 
 | 
 
 | 
  
    |  |  |  | 
 | 
 | 
 | raise 
 lower
 | 10 - 14 V 
 0 - 1 V
 |  27.1, 
 Control module (N52).
 | 
  
    | 27.1 |  | Y56y5 Resistance
 | 11
  | N52  
        X     | 
          5 | Disconnect test cable (X) from control
      module (N52). | 
 5 - 15
  | Wiring, Y56y5,
 If nominal value is obtained: N52.
 | 
  
    | 28.0 |  | Soft top "open" valve (Y55y6)
      circuit Voltage supply
 | 
 11
  | N52  
        X     | 
        
          1 | Ignition: ON Operate soft top using power soft top switch (S84):
 | 
 
 |  | 
  
    |  |  |  | 
 
 |  | 
 
 | opening 
 closing
 | 10 - 14 V 
 0 - 1 V
 |  28.1, 
 Control module (N52).
 | 
  
    | 28.1 |  | Y55y6 Resistance
 | 
 11
  | N52  
        X     | 
        
          1 | Disconnect test cable (X) from control
      module (N52). | 
 5 - 15
  | Wiring, Y55y6,
 If nominal value is obtained: N52.
 | 
  
    | 29.0 |  | Soft top "close" valve (Y55y7)
      circuit Voltage supply
 | 
 11
  | N52  
        X     | 
        
          2 | Ignition: ON Operate soft top using power soft top switch (S84):
 | 
 
 | 
 
 | 
  
    |  |  |  | 
 |  | 
 | closing 
 opening
 | 10 - 14 V 
 0 - 1 V
 
 |  29.1, 
 Control module (N52).
 | 
  
    | 29.1 |  | Y55y7 Resistance
 | 
 11
  | N52  
        X     | 
        
          2 | Disconnect test cable (X) from control
      module (N52). | 
 5 - 15
  | Wiring, Y55y7,
 If nominal value is obtained: N52.
 | 
  
    | 30.0 |  | Fabric bow "raise" valve (Y55y8)
      circuit Voltage supply
 | 
 11
  | N52  
        X     | 
        
          3 | Ignition: ON Operate fabric bow using power soft top switch (S84) to:
 | 
 
 |  | 
  
    |  |  |  | 
 
 |  | 
 
 | raise 
 lower
 | 10 - 14 V 
 0 - 1 V
 |  30.1, 
 Control module (N52).
 | 
  
    | 30.1 |  | Y55y8 Resistance
 | 
 11
  | N52  
        X     | 
        
          3 | Disconnect test cable (X) from control
      module (N52). | 
 5 - 15
  | Wiring, Y55y8,
 If nominal value is obtained: N52.
 
 | 
  
    | 31.0 |  | Fabric bow "lower" valve (Y55y9)
      circuit Voltage supply
 | 
 11
  | N52  
        X     | 
        
          4 | Ignition: ON Operate fabric bow using power soft top switch (S84) to:
 | 
 
 | 
 
 | 
  
    |  |  |  | 
 |  | 
 | lower 
 raise
 | 10 - 14 V 
 0 - 1 V
 
 |  31.1, 
 Control module (N52).
 | 
  
    | 31.1 |  | Y55y9 Resistance
 | 
 11
  | N52  
        X     | 
        
          4 | Disconnect test cable (X) from control
      module (N52). | 
 5 - 15
  | Wiring, Y55y9,
 If nominal value is obtained: N52.
 | 
  
    | 32.0 |  | Combination relay (heated rear
      window, N10) Voltage supply
 | 
 6
  | N52  
        Z     | 
        
          12 | Soft top opened. | Multimeter display blinks (approx.
      2 Hz). 
 
 | Wiring, Soft top "overhead" switch (S84/4),
 Control module (N52).
 | 
  
    | 33.0 |  | CF control module (N57) Voltage supply
 | 
 27
  | N52  
        Y     | 
        
          28 | Ignition: ON Tap power soft top switch (S84) twice and hold:
 | 0 - 1 V 
 
 | Wiring, Control module (N52),
 CF control module (N57).
 | 
  
    |  |  |  | 
 
 |  | 
 
 | in opening position 
 in closing position
 | -9 to -14V 
 9 - 14 V
 | 
 
 | 
  
    | 34.0 |  | Ceiling control panel warning
      buzzer | 
 
  | N52  
        Y     | 
        
          33 | Ignition: ON 
 
 | Tone sounds. 
 
 | Wiring, Dome lamp (with shut off delay) (E15).
 | 
  
    | 35.0 |  | Indicator lamp power soft top
      switch (S84) Voltage supply
 | 4
  | S84   | 
          2 | Ignition: ON | 11 - 14 V 
 | Wiring. | 
  
    | 36.0 |  | Signal to power soft top switch
      indicator lamp (S84) | 
 
 |  | 
 
 | Soft top completely closed or opened. Ignition: ON
 | Indicator lamp should light for approx.
      1 s. | Wiring, S84,
 Control module (N52).
 | 
  
    | 37.0 |  | RB control module (N53) | 
 
   
 
 
 
 
  |  |  | Ignition: ON | > 2.4 V 
 
 
 
 
 
 > 2.4 V
 | Wiring, Malfunction in roll bar system (see DM, Body and Accessories, Vol. 3,
 section 19.1),
 Control module (N53).
 |