Electrical Test Program - Soft Top Tester Nominal Values
Soft top menu protocol
Note: Time and pressure specifications must be achieved during a normal/smooth
and consistant soft top operational sequence (at room temperature). As long
as the time specification is attained, the pressure readings are of secondary
importance. System hydraulic pressure should be recorded as the limit switch
activates.
Table I
Closing soft top
Time in seconds
Pressure in bar
Unlock soft top compartment cover
1.5
200
Raise soft top compartment cover
6.0
200
Raise soft top (differential operation)
and engage in front locks
10-14
140
Lock front locks
1.8
200
Close soft top compartment cover
2.5
200
Lock soft top compartment cover
2.5
200
Close fabric bow
3.0
200
Lock fabric bow
3.0
200
Table II
Opening soft top
Time in seconds
Pressure in bar
Unlock fabric bow
1.5
200
Raise fabric bow
3.0
200
Unlock soft top compartment cover
1.5
200
Raise soft top compartment cover
6.0
200
Open front lock
2.0
200
Open soft top
15.0
200
Close soft top compartment cover
2.5
200
Lock soft top compartment cover
2.5
200
Table III
Menu, front locks
Switch point in mm before main
detent
Soft top
0.12-0.35
Menu, center locks
Left/right center lock limit switch,
closed
42.0-43.1
Left/right center lock limit switch,
locked
1.97-2.83
Menu, rear locks
Left/right rear lock limit switch,
closed
42.0-43.1
Left/right rear lock limit switch,
locked
1.97-2.83
Menu, sealing
Pressure must not fall below nominal
value of 120 bar.