Electrical Test Program - Soft Top Tester Nominal Values

Soft top menu protocol
Note:
Time and pressure specifications must be achieved during a normal/smooth and consistant soft top operational sequence (at room temperature). As long as the time specification is attained, the pressure readings are of secondary importance. System hydraulic pressure should be recorded as the limit switch activates.


Table I

Closing soft top Time in seconds Pressure in bar
Unlock soft top compartment cover 1.5 200
Raise soft top compartment cover 6.0 200
Raise soft top (differential operation)
and engage in front locks
10-14 140
Lock front locks 1.8 200
Close soft top compartment cover 2.5 200
Lock soft top compartment cover 2.5 200
Close fabric bow 3.0 200
Lock fabric bow 3.0 200

Table II
Opening soft top Time in seconds Pressure in bar
Unlock fabric bow 1.5 200
Raise fabric bow 3.0 200
Unlock soft top compartment cover 1.5 200
Raise soft top compartment cover 6.0 200
Open front lock 2.0 200
Open soft top 15.0 200
Close soft top compartment cover 2.5 200
Lock soft top compartment cover 2.5 200

Table III
Menu, front locks Switch point in mm before main detent
Soft top 0.12-0.35
Menu, center locks  
Left/right center lock limit switch, closed 42.0-43.1
Left/right center lock limit switch, locked 1.97-2.83
Menu, rear locks  
Left/right rear lock limit switch, closed 42.0-43.1
Left/right rear lock limit switch, locked 1.97-2.83
Menu, sealing  
Pressure must not fall below nominal value of 120 bar.