Operational sequence, opening hardtop |
Limit switches engaged
1) corresponds to: Voltage measurements at the socket box
(V)
2) corresponds to: Readouts on the HHT |
Retractable hardtop
|
Trunk lid
|
Cover
in trunk |
Rotary
latch |
locked
right |
locked
left |
closed
|
open/
stored |
open
|
closed/
locked |
closed
|
closed
|
S69/2
|
S69/3
|
S69/1
|
S69/11 |
S69/9 |
S69/7
S69/8 |
S69/10 |
S69/12 |
Connection Diagram - Socket Box
( 22) |
30 |
30 |
32 |
33 |
52 |
37 |
54 |
69 |
Rest position, hardtop closed |
1) 0-1
2) Yes |
1) 0-1
2) Yes |
1) 0-1
2) Yes |
1) 11-14
2) No |
1) 11-14
2) No |
1) 0-1
2) Yes |
1) 0-1
2) Closed |
1) 0-1
2) Closed |
Side windows open,
Trunk lid unlocked, open and,
Retractable hardtop unlocked |
1) 11-14
2) No |
1) 11-14
2) No |
1) 0-1
2) Yes |
1) 11-14
2) No |
1) 0-1
2) Yes |
1) 11-14
2) No |
1) 0-1
2) Closed |
1) 0-1
2) Closed |
Retractable hardtop open/stored,
Front side windows open |
1) 11-14
2) No |
1) 11-14
2) No |
1) 11-14
2) No |
1) 0-1
2) Yes |
1) 0-1
2) Yes |
1) 11-14
2) No |
1) 0-1
2) Closed |
1) 0-1
2) Closed |
Trunk lid closed and locked and
Retractable hardtop locked |
1) 0-1
2) Yes |
1) 0-1
2) Yes |
1) 11-14
2) No |
1) 0-1
2) Yes |
1) 11-14
2) No |
1) 0-1
2) Yes |
1) 0-1
2) Closed |
1) 0-1
2) Closed |
After locking, elapsed time t=2 sec.,
Rear side windows go down for time t=2 sec. |
1) 0-1
2) Yes |
1) 0-1
2) Yes |
1) 11-14
2) No |
1) 0-1
2) Yes |
1) 11-14
2) No |
1) 0-1
2) Yes |
1) 0-1
2) Closed |
1) 0-1
2) Closed |
Front side windows go up. |
1) 0-1
2) Yes |
1) 0-1
2) Yes |
1) 11-14
2) No |
1) 0-1
2) Yes |
1) 11-14
2) No |
1) 0-1
2) Yes |
1) 0-1
2) Closed |
1) 0-1
2) Closed |
Operational sequence, closing hardtop |
Limit switches engaged
1) corresponds to: Voltage measurements (V) at the socket
box
2) corresponds to: Readouts on the HHT |
Retractable hardtop
|
Trunk lid
|
Cover
in trunk |
Rotary
latch |
locked
right |
locked
left |
closed
|
open/
stored |
open
|
closed/
locked |
closed
|
closed
|
S69/2
|
S69/3
|
S69/1
|
S69/11 |
S69/9 |
S69/7
S69/8 |
S69/10 |
S69/12 |
Connection Diagram - Socket Box
( 22) |
30 |
30 |
32 |
33 |
52 |
37 |
54 |
69 |
Rest position, Hardtop open |
1) 0-1
2) Yes |
1) 0-1
2) Yes |
1) 11-14
2) No |
1) 0-1
2) Yes |
1) 11-14
2) No |
1) 0-1
2) Yes |
1) 0-1
2) Closed |
1) 0-1
2) Closed |
Side windows open,
Trunk lid unlocked, open and,
Retractable hardtop unlocked |
1) 11-14
2) No |
1) 11-14
2) No |
1) 11-14
2) No |
1) 0-1
2) No |
1) 0-1
2) Yes |
1) 11-14
2) No |
1) 0-1
2) Closed |
1) 0-1
2) Closed |
Retractable hardtop closed,
Open side windows |
1) 11-14
2) No |
1) 11-14
2) No |
1) 0-1
2) Yes |
1) 11-14
2) No |
1) 0-1
2) Yes |
1) 11-14
2) No |
1) 0-1
2) Closed |
1) 0-1
2) Closed |
Trunk lid closed, locked and hardtop
locked |
1) 0-1
2) Yes |
1) 0-1
2) Yes |
1) 0-1
2) Yes |
1) 11-14
2) No |
1) 11-14
2) No |
1) 0-1
2) Yes |
1) 0-1
2) Closed |
1) 0-1
2) Closed |
After locking, time t=0.3 sec.,
Rear side windows go down for time t=3 sec., |
1) 0-1
2) Yes |
1) 0-1
2) Yes |
1) 0-1
2) Yes |
1) 11-14
2) No |
1) 11-14
2) No |
1) 0-1
2) Yes |
1) 0-1
2) Closed |
1) 0-1
2) Closed |
Operational sequence, closing hardtop |
Limit switches engaged
1) corresponds to: Voltage measurements (V) at the socket
box
2) corresponds to: Readouts on the HHT |
Retractable hardtop
|
Trunk lid
|
Cover
in trunk |
Rotary
latch |
locked
right |
locked
left |
closed
|
open/
stored |
open
|
closed/
locked |
closed
|
closed
|
S69/2
|
S69/3
|
S69/1
|
S69/11 |
S69/9 |
S69/7
S69/8 |
S69/10 |
S69/12 |
Rear side windows go up (close) |
1) 0-1
2) Yes |
1) 0-1
2) Yes |
1) 0-1
2) Yes |
1) 11-14
2) No |
1) 11-14
2) No |
1) 0-1
2) Yes |
1) 0-1
2) Closed |
1) 0-1
2) Closed |
Side windows go up (close) |
1) 0-1
2) Yes |
1) 0-1
2) Yes |
1) 0-1
2) Yes |
1) 11-14
2) No |
1) 11-14
2) No |
1) 0-1
2) Yes |
1) 0-1
2) Closed |
1) 0-1
2) Closed |
Operational sequence, opening retractable hardtop |
Limit switches engaged
1) corresponds to: Voltage measurements at the socket box
(V)
2) corresponds to: Readouts on the HHT |
Power window motors actuation.
|
right rear (M10/6) |
Connection Diagram - Socket Box
( 22)
|
13 12 |
11 10 |
17 16 |
15 14 |
Front side windows open,
Rear side windows go down for time t=3 sec.,
Trunk lid unlocks, opens and,
Hardtop unlocks |
1) -11 to -14 volts
2) open |
1) -11 to -14 volts
2) open |
1) -11 to -14 volts
2) open |
1) -11 to -14 volts
2) open |
Retractable hardtop open (stored)
Front side windows go down |
1) -11 to -14 volts
2) open |
1) -11 to -14 volts
2) open |
1) 0 - 1 V
2) not actuated |
1) 0 - 1 V
2) not actuated |
Trunk lid closes, locks and
Retractable hardtop locks |
1) 0 - 1 V
2) not actuated |
1) 0 - 1 V
2) not actuated |
1) 0 - 1 V
2) not actuated |
1) 0 - 1 V
2) not actuated |
After locking, time t=2 sec
Rear side windows go down for time t=2 sec |
1) 0 - 1 V
2) not actuated |
1) 0 - 1 V
2) not actuated |
1) -11 to --14 volts
2) open |
1) -11 to -14 volts
2) open |
Front side windows go up |
1) 11 to 14 volts
2) close |
1) 11 to 14 volts
2) close |
1) 0 - 1 V
2) not actuated |
1) 0 - 1 V
2) not actuated |
Operational sequence, closing retractable hardtop |
Limit switches engaged
1) corresponds to: Voltage measurenents at the socket box
(V)
2) corresponds to: Readouts on the HHT |
Power window motors actuation.
|
right rear (M10/6) |
Connection Diagram - Socket Box
( 22)
|
13 12 |
11 10 |
17 16 |
15 14 |
Front side windows go down,
Trunk lid unlocks, opens and,
Hardtop unlocks |
1) -11 to -14 volts
2) open |
1) -11 to -14 volts
2) open |
1) 0 - 1 V
2) not actuated |
1) 0 - 1 V
2) not actuated |
Retractable hardtop closes,
Front side windows go down |
1) -11 to -14 volts
2) open |
1) -11 to -14 volts
2) open |
1) 0 - 1 V
2) not actuated |
1) 0 - 1 V
2) not actuated |
Trunk lid closes, locks, and
Hardtop locks |
1) 0 - 1 V
2) not actuated |
1) 0 - 1 V
2) not actuated |
1) 0 - 1 V
2) close |
1) 0 - 1 V
2) close |
After locking time t=3 sec.
Rear side windows go up |
1) 0 - 1 V
2) not actuated |
1) 0 - 1 V
2) not actuated |
1) 11 to 14 volts
2) close |
1) 11 to 14 volts
2) close |
Front side windows go up |
1) 11 to 14 volts
2) close |
1) 11 to 14 volts
2) close |
1) 0 - 1 V
2) not actuated |
1) 0 - 1 V
2) not actuated |
|