STI Home
Diagnostic Manual, Body and Accessories,
Volume 3

 Printable version
LOCATION:    11.4 Retractable Hardtop (RH)   >  24 Electrical Test Program - Survey of Electrical Limit Switch Signals


Electrical Test Program - Survey of Electrical Limit Switch Signals

Operational sequence, opening hardtop
Limit switches engaged


1) corresponds to: Voltage measurements at the socket box (V)
2) corresponds to: Readouts on the HHT
Retractable hardtop
Trunk lid
Cover
in trunk
Rotary
latch
locked
right
locked
left
closed
open/
stored
open
closed/
locked
closed
closed
S69/2
S69/3
S69/1
S69/11 S69/9 S69/7
S69/8
S69/10 S69/12
Connection Diagram - Socket Box
( 22)

30

30

32

33

52

37

54

69
Rest position, hardtop closed 1) 0-1
2) Yes
1) 0-1
2) Yes
1) 0-1
2) Yes
1) 11-14
2) No
1) 11-14
2) No
1) 0-1
2) Yes
1) 0-1
2) Closed
1) 0-1
2) Closed
Side windows open,
Trunk lid unlocked, open and,
Retractable hardtop unlocked
1) 11-14
2) No
1) 11-14
2) No
1) 0-1
2) Yes
1) 11-14
2) No
1) 0-1
2) Yes
1) 11-14
2) No
1) 0-1
2) Closed
1) 0-1
2) Closed
Retractable hardtop open/stored,
Front side windows open
1) 11-14
2) No
1) 11-14
2) No
1) 11-14
2) No
1) 0-1
2) Yes
1) 0-1
2) Yes
1) 11-14
2) No
1) 0-1
2) Closed
1) 0-1
2) Closed
Trunk lid closed and locked and
Retractable hardtop locked
1) 0-1
2) Yes
1) 0-1
2) Yes
1) 11-14
2) No
1) 0-1
2) Yes
1) 11-14
2) No
1) 0-1
2) Yes
1) 0-1
2) Closed
1) 0-1
2) Closed
After locking, elapsed time t=2 sec.,
Rear side windows go down for time t=2 sec.
1) 0-1
2) Yes
1) 0-1
2) Yes
1) 11-14
2) No
1) 0-1
2) Yes
1) 11-14
2) No
1) 0-1
2) Yes
1) 0-1
2) Closed
1) 0-1
2) Closed
Front side windows go up. 1) 0-1
2) Yes
1) 0-1
2) Yes
1) 11-14
2) No
1) 0-1
2) Yes
1) 11-14
2) No
1) 0-1
2) Yes
1) 0-1
2) Closed
1) 0-1
2) Closed

Operational sequence, closing hardtop
Limit switches engaged


1) corresponds to: Voltage measurements (V) at the socket box
2) corresponds to: Readouts on the HHT
Retractable hardtop
Trunk lid
Cover
in trunk
Rotary
latch
locked
right
locked
left
closed
open/
stored
open
closed/
locked
closed
closed
S69/2
S69/3
S69/1
S69/11 S69/9 S69/7
S69/8
S69/10 S69/12
Connection Diagram - Socket Box
( 22)

30

30

32

33

52

37

54

69
Rest position, Hardtop open 1) 0-1
2) Yes
1) 0-1
2) Yes
1) 11-14
2) No
1) 0-1
2) Yes
1) 11-14
2) No
1) 0-1
2) Yes
1) 0-1
2) Closed
1) 0-1
2) Closed
Side windows open,
Trunk lid unlocked, open and,
Retractable hardtop unlocked
1) 11-14
2) No
1) 11-14
2) No
1) 11-14
2) No
1) 0-1
2) No
1) 0-1
2) Yes
1) 11-14
2) No
1) 0-1
2) Closed
1) 0-1
2) Closed
Retractable hardtop closed,
Open side windows
1) 11-14
2) No
1) 11-14
2) No
1) 0-1
2) Yes
1) 11-14
2) No
1) 0-1
2) Yes
1) 11-14
2) No
1) 0-1
2) Closed
1) 0-1
2) Closed
Trunk lid closed, locked and hardtop locked 1) 0-1
2) Yes
1) 0-1
2) Yes
1) 0-1
2) Yes
1) 11-14
2) No
1) 11-14
2) No
1) 0-1
2) Yes
1) 0-1
2) Closed
1) 0-1
2) Closed
After locking, time t=0.3 sec.,
Rear side windows go down for time t=3 sec.,
1) 0-1
2) Yes
1) 0-1
2) Yes
1) 0-1
2) Yes
1) 11-14
2) No
1) 11-14
2) No
1) 0-1
2) Yes
1) 0-1
2) Closed
1) 0-1
2) Closed

Operational sequence, closing hardtop
Limit switches engaged


1) corresponds to: Voltage measurements (V) at the socket box
2) corresponds to: Readouts on the HHT
Retractable hardtop
Trunk lid
Cover
in trunk
Rotary
latch
locked
right
locked
left
closed
open/
stored
open
closed/
locked
closed
closed
S69/2
S69/3
S69/1
S69/11 S69/9 S69/7
S69/8
S69/10 S69/12
Rear side windows go up (close) 1) 0-1
2) Yes
1) 0-1
2) Yes
1) 0-1
2) Yes
1) 11-14
2) No
1) 11-14
2) No
1) 0-1
2) Yes
1) 0-1
2) Closed
1) 0-1
2) Closed
Side windows go up (close) 1) 0-1
2) Yes
1) 0-1
2) Yes
1) 0-1
2) Yes
1) 11-14
2) No
1) 11-14
2) No
1) 0-1
2) Yes
1) 0-1
2) Closed
1) 0-1
2) Closed

Operational sequence, opening retractable hardtop
Limit switches engaged


1) corresponds to: Voltage measurements at the socket box (V)
2) corresponds to: Readouts on the HHT
Power window motors actuation.


right rear (M10/6)
Connection Diagram - Socket Box
( 22)

13 12

11 10

17 16

15 14
Front side windows open,
Rear side windows go down for time t=3 sec.,
Trunk lid unlocks, opens and,
Hardtop unlocks

1) -11 to -14 volts
2) open

1) -11 to -14 volts
2) open

1) -11 to -14 volts
2) open

1) -11 to -14 volts
2) open
Retractable hardtop open (stored)
Front side windows go down
1) -11 to -14 volts
2) open
1) -11 to -14 volts
2) open
1) 0 - 1 V
2) not actuated
1) 0 - 1 V
2) not actuated
Trunk lid closes, locks and
Retractable hardtop locks
1) 0 - 1 V
2) not actuated
1) 0 - 1 V
2) not actuated
1) 0 - 1 V
2) not actuated
1) 0 - 1 V
2) not actuated
After locking, time t=2 sec
Rear side windows go down for time t=2 sec
1) 0 - 1 V
2) not actuated
1) 0 - 1 V
2) not actuated
1) -11 to --14 volts
2) open
1) -11 to -14 volts
2) open
Front side windows go up 1) 11 to 14 volts
2) close
1) 11 to 14 volts
2) close
1) 0 - 1 V
2) not actuated
1) 0 - 1 V
2) not actuated

Operational sequence, closing retractable hardtop
Limit switches engaged


1) corresponds to: Voltage measurenents at the socket box (V)
2) corresponds to: Readouts on the HHT
Power window motors actuation.


right rear (M10/6)
Connection Diagram - Socket Box
( 22)

13 12

11 10

17 16

15 14
Front side windows go down,
Trunk lid unlocks, opens and,
Hardtop unlocks
1) -11 to -14 volts
2) open
1) -11 to -14 volts
2) open
1) 0 - 1 V
2) not actuated
1) 0 - 1 V
2) not actuated
Retractable hardtop closes,
Front side windows go down
1) -11 to -14 volts
2) open
1) -11 to -14 volts
2) open
1) 0 - 1 V
2) not actuated
1) 0 - 1 V
2) not actuated
Trunk lid closes, locks, and
Hardtop locks
1) 0 - 1 V
2) not actuated
1) 0 - 1 V
2) not actuated
1) 0 - 1 V
2) close
1) 0 - 1 V
2) close
After locking time t=3 sec.
Rear side windows go up
1) 0 - 1 V
2) not actuated
1) 0 - 1 V
2) not actuated
1) 11 to 14 volts
2) close
1) 11 to 14 volts
2) close
Front side windows go up 1) 11 to 14 volts
2) close
1) 11 to 14 volts
2) close
1) 0 - 1 V
2) not actuated
1) 0 - 1 V