11.4 Retractable Hardtop (RH)
> 24 Electrical Test Program - Survey of Electrical Valve Actuation
Electrical Test Program - Survey of Electrical Valve Actuation
Operational sequence, retractable hardtop opening
Limit switches engaged
1)
corresponds to:
Voltage measurements (V) at the socket box
2) corresponds to: Readouts on the HHT
Hydraulic unit relay (A7/5k1)
Retractable hardtop solenoid valve (A7/5y1)
Trunk lid solenoid valve (A7/5y2)
Connection Diagram - Socket Box
(
22
)
22
24
25
Front and rear side windows go down
Trunk lid unlocks, opens and
Retractable hardtop unlocks
1)
11 - 14 V
2) ON
1)
11 - 14 V
2) ON
1)
11 - 14 V
2) ON
Retractable hardtop opens
Front side windows open
1)
11 - 14 V
2) ON
1) 0-1 V
2) OFF
1)
11 - 14 V
2) ON
Trunk lid closes, locks and hardtop locks
1)
11 - 14 V
2) ON
1) 0-1 V
2) OFF
1) 0-1 V
2) OFF
After locking, time t=2 sec.
Rear side windows go down for t=2 sec.
1)
11 - 14 V
2) ON
1) 0-1 V
2) OFF
1) 0-1 V
2) OFF
Front side windows go up
1) 0-1 V
2) OFF
1) 0-1 V
2) OFF
1) 0-1 V
2) OFF
Operational sequence, retractable hardtop closing
Limit switches engaged
1)
corresponds to:
Voltage measurements at the socket box (V)
2) corresponds to: Readouts on the HHT
Hydraulic unit relay (A7/5k1)
Retractable hardtop solenoid valve (A7/5y1)
Trunk lid solenoid valve (A7/5y2)
Connection Diagram - Socket Box
(
22
)
22
24
25
Front and rear side windows go down
Trunk lid unlocks, opens and
Retractable hardtop unlocks
1)
11 - 14 V
2) ON
1) 0-1 V
2) OFF
1)
11 - 14 V
2) ON
Retractable hardtop opens
Front side windows go down
1)
11 - 14 V
2) ON
1)
11 - 14 V
2) ON
1)
11 - 14 V
2) ON
Trunk lid closes, locks and hardtop locks
1)
11 - 14 V
2) ON
1)
11 - 14 V
2) ON
1) 0-1 V
2) OFF
After locking, elapsed time t=3 sec.
Rear side windows go up for time t=3 sec.
1)
11 - 14 V
2) ON
1)
11 - 14 V
2) ON
1) 0-1 V
2) OFF
Rear side windows go up
1) 0-1 V
2) OFF
1) 0-1 V
2) OFF
1) 0-1 V
2) OFF
Front side windows go up
1) 0-1 V
2) OFF
1) 0-1 V
2) OFF
1) 0-1 V
2) OFF