Test scope |
Test connection
|
Test condition |
Nominal value |
Possible cause/ Remedy |
1.0 |
|
Roll bar control module power soft
top (N52)
Voltage supply, terminal 30 for soft top electronics |
51
52 |
|
4
41
|
|
11-14 V
11-14 V |
Wiring. |
1.1 |
|
Voltage supply, terminal 30 for left
rear power window |
3 |
N52
|
40
|
Left rear power window operated
|
11-14 V
11-14 V |
Wiring. |
1.2 |
|
Voltage supply, terminal 30 for right
rear power window |
21 |
N52
|
38
|
Right rear power window operated
|
11-14 V
11-14 V |
Wiring. |
1.3 |
|
Voltage supply, terminal 15 |
51 |
N52
|
14
|
Ignition: ON |
11-14 V
|
Wiring. |
2.0 |
|
Roll bar control module power soft
top (N52)
Voltages on CAN data buses:
Voltage on CAN LOW line
Voltage on CAN HIGH line |
|
|
|
Ignition: ON
|
3.2 V (oscillating)
1.8 V (oscillating)
|
Wiring,
Read out DTC's from control modules of CAN interior bus using HHT.
Value OK:
2.1 |
2.1 |
|
Voltage between CAN LOW and CAN high
line |
37 |
N52
|
19
|
Ignition: OFF
Ignition: ON
Ignition: OFF
after approx. 30 seconds ("Sleep mode")
|
-
1.4 V
1.4 V
4.8 V
|
Wiring,
Read out DTC's from control modules of CAN interior bus using HHT. |
3.0 |
|
Power soft top switch (S84)
Voltage supply and signal voltages. |
52 |
|
N52
55
|
Ignition: ON
S84 in rest position.
S84 operated towards "close soft top".
S84 operated towards "open soft top".
|
-
11 - 14 V
0 - 1 V
Approx. 3V |
Roll bar control module power soft
top (N52).
3.1 |
3.1 |
|
Resistance |
52 |
N52
|
55
|
Ignition: OFF
Test cable disconnected from control module.
S84 in rest position.
S84 operated towards "open soft top".
S84 operated towards "close soft top". |
> 20 k
Approx.
200
approx. 1
|
Only one value not OK:
S84.
Several values not OK:
wiring,
or
S84. |
4.0 |
|
Indicator lamp in power soft top
switch (S84)
Voltage supply from roll bar control module (power soft top) (N52)
|
1 |
S84
|
2
|
Connector on S84 disconnected.
Soft top unlocked manually.
Ignition: ON |
approx. 11 V |
N52,
Nominal value OK, but still inoperative when connector is plugged in:
Wiring,
S84.
Value OK:
4.1
|
4.1 |
|
Illumination |
1 |
S84
|
5
|
Connector on S84 disconnected
Exterior lamp switch S1 (terminal 58d): ON
Adjust maximum brightness at instrument cluster (A1)
|
approx. 11 V |
Wiring,
Value OK but still no illumination when connector is plugged in:
S84. |
5.0 |
|
RB hydraulic unit (power soft top);
hydraulic unit relay (A7/5k1), voltage supply, terminal 30 measured
at relay base. |
4 |
A7/5k1
|
2
|
A7/5k1 disconnected |
11-14 V
|
Wiring,
Value OK
5.1 |
5.1 |
|
Actuation of RB hydraulic unit (power
soft top); hydraulic unit relay (A7/5k1) by roll bar control module (power
soft top) (N52) measured at relay base. |
4 |
A7/5k1
|
6
|
Roll bar:
Retracted.
A7/5k1 disconnected.
Ignition: OFF and ON again.
RB switch (manual operation) (S83) operated towards "extend roll bar"
|
11-14 V
|
Wiring,
Value OK
5.2
Value OK
5.3 |
5.2 |
|
Actuation of A7/5k1 by N52, measured
at N52 |
52 |
N52
|
42
|
Roll bar:
Retracted.
A7/5k1 plugged in.
Socket box connected.
Ignition: OFF and ON again
S83 operated towards "extend roll bar"
|
11-14 V |
S83,
Voltage supply from
N52
Value OK:
Wiring. |
5.3 |
|
Voltage supply, terminal 30 under
load, measured at relay base |
4 |
A7/5k1
|
2
|
Roll bar:
Retracted.
A7/5k1 plugged in.
S83 operated towards "extend roll bar" |
11-14 V
|
Wiring,
Value OK
5.4 |
5.4 |
|
Output voltage of RB hydraulic unit
(power soft top) relay (A7/5k1), measured at relay base |
4 |
A7/5k1
|
8
|
Roll bar:
Retracted.
A7/5k1 plugged in.
Ignition: ON
S83 operated towards "extend roll bar"
|
11-14 V |
A7/5k1. |
6.0 |
|
Resistance of RB hydraulic unit
(power soft top) motor (A7/5m1), measured at relay base |
|
|
A7/5k1
8
|
A7/5k1 at RB hydraulic unit (power
soft top) (A7/5).
Ignition: OFF
|
approx. 1
|
Wiring,
A7/5m1. |
7.0 |
|
Resistance of RB hydraulic unit
(power soft top) overload protection thermocouple (A7/5b1)
measured at roll bar control module (power soft top) (N52) |
32 |
N52
|
18
|
Test cable at N52 disconnected.
Ignition: OFF
Pump temperature:
25 °C
30 °C
40 °C
120 °C |
220±22 k
178±18 k
121±12.5 k
10± 2 k
|
Wiring
7.1 |
7.1 |
|
Resistance of RB hydraulic unit (power
soft top) connector (A7/5x1) |
2 |
A7/5x1
|
1
|
Test cable at N52 disconnected.
Ignition: OFF
Pump temperature:
25 °C
30 °C
40 °C
120 °C |
220±22 k
178±18 k
121±12.5 k
10± 2 k
|
A7/5b1. |
8.0 |
|
Retractable luggage cover engaged
limit switch (S69/10)
Voltage supply and signal voltage |
|
|
N52
28
|
Ignition: ON
Trunk luggage cover:
Pulled out
Rolled in |
0-1 V
11-14 V
|
Both values not OK: roll bar
control module (power soft top) (N52),
One value not OK:
8.1
|
8.1 |
|
Resistance |
|
|
N52
28
|
Ignition: OFF
Disconnect test cable from control module.
Trunk luggage cover:
Pulled out
Rolled in |
0-5
> 20 k
|
Wiring.
S69/10,
Value OK:
N52 |
9.0 |
|
Soft top locked (left) limit switch
(S84/11)
Voltage supply and signal voltage |
|
|
N52
15
|
Ignition: ON
Soft top:
Locked
Unlocked
|
0-1 V
11-14 V |
Both values not OK:
Roll bar control module (power soft top) (N52),
One value not OK:
9.1 |
9.1 |
|
Resistance |
|
|
N52
15
|
Ignition: OFF
Disconnect test cable from control module.
Soft top:
Locked
Unlocked |
0-5
> 20 k
|
Wiring.
S84/11.
Value OK:
N52. |
10.0 |
|
Soft top opened limit switch (S84/13s2)
Voltage supply and signal voltage |
|
|
N52
33
|
Ignition: ON
Soft top:
Completely open
Closed
|
0-1 V
11-14 V |
Both values not OK:
N52.
One value not OK:
10.1 |
10.1 |
|
Resistance |
|
|
N52
33
|
Ignition: OFF
Test cable disconnected from control module.
Soft top:
Open
Completely open |
> 20 k
0-5
|
Wiring.
Soft top opened limit switch (S84/13s2).
Value OK:
Roll bar control module (power soft top) (N52).
|
11.0 |
|
Soft top closed limit switch (S84/13s1)
Voltage supply and signal voltage |
|
|
N52
31
|
Ignition: ON
Soft top:
Completely closed
Open |
0-1 V
11-14 V
|
Both values not OK:
N52.
One value not OK:
11.1 |
11.1 |
|
Resistance |
|
|
N52
31
|
Ignition: OFF
Test cable disconnected from control module.
Soft top:
Open
Completely closed |
> 20 k
0-5
|
Wiring.
S84/13s1.
Value OK:
N52. |
12.0 |
|
Soft top compartment "open"
switch (S84/5)
Voltage supply and signal voltage |
|
|
N52
50
|
Ignition: ON
Soft top compartment cover:
Completely open
Closed |
0-1 V
11-14 V
|
Both values not OK:
Roll bar control module (power soft top) (N52).
Only one value not OK:
12.1 |
12.1 |
|
Resistance |
|
|
N52
50
|
Ignition: OFF
Test cable disconnected from control module:
Soft top compartment cover:
Completely open
Closed |
0-5
> 20 k
|
Wiring.
S84/5.
Value OK:
N52. |
13.0 |
|
Soft top compartment closed limit
switch (A25s1)
Voltage supply and signal voltage |
|
|
N52
47
|
Ignition: ON
Soft top compartment cover:
Closed
Open |
0-1 V
11-14 V
|
Both values not OK
N52.
One value not OK:
13.1 |
13.1 |
|
Resistance |
|
|
N52
47
|
Ignition: OFF
Test cable disconnected from control module
Soft top compartment cover:
Open
Closed |
> 20 k
0-5 |
Wiring
Soft top compartment closed limit switch (A25s1).
Value OK:
Roll bar control module (power soft top) (N52).
|
14.0 |
|
Soft top compartment locked limit
switch (A25s2)
Voltage supply and signal voltage |
|
|
N52
10
|
Soft top compartment cover:
Locked
Unlocked
|
0-1 V
11-14 V |
Both values not OK:
N52.
One value not OK:
14.1 |
14.1 |
|
Resistance |
|
|
N52
10
|
Ignition: OFF
Disconnect test cable from control module
Soft top compartment cover:
Locked
Unlocked |
0-5
> 20 k |
Wiring.
A25s2.
Value OK:
N52. |
15.0 |
|
Soft top fabric bow up/down limit
switch (S84/15)
Voltage supply and signal voltage of "soft top bow down"switch
contact |
|
|
N52
11
|
Ignition: ON
Soft top bow:
Completely down
Up |
0-1 V
11-14 V |
Both values not OK:
Roll bar control module (power soft top) (N52).
One value not OK:
15.2
Value OK:
15.1
|
15.1 |
|
Voltage supply and signal voltage
of "soft top bow up" switch contact |
|
|
N52
13
|
Ignition: ON
Soft top bow:
Completely up
Down |
0-1 V
11-14 V
|
Both values not OK:
N52.
One value not OK:
15.3 |
15.2 |
|
Resistance of "soft top bow down"
switch contact |
|
|
N52
11
|
Ignition: OFF
Disconnect test cable from control module
Soft top bow:
Up
Completely down |
> 20 k
0-5
|
Wiring.
S84/15.
Value OK:
N52. |
15.3 |
|
Resistance of "soft top bow up"
switch contact |
|
|
N52
13
|
Ignition: OFF
Disconnect test cable from control module.
Soft top bow:
Down
Completely up |
> 20 k
0-5
|
Wiring.
Soft top fabric bow up/down limit switch (S84/15).
Value OK:
Roll bar control module (power soft top) (N52).
|
16.0 |
|
Soft top bow locked limit switch
(S84/16)
Voltage supply and signal voltage |
|
|
N52
29
|
Ignition: ON
Soft top bow:
Locked
Unlocked |
0-1 V
11-14 V
|
Both values not OK:
N52.
One value not OK:
16.1
|
16.1 |
|
Resistance |
|
|
N52
29
|
Ignition: OFF
Test cable disconnected from control
module
Soft top bow:
Unlocked
Locked |
> 20 k
0-5
|
Wiring.
S84/16.
Value OK:
N52. |
17.0 |
|
RB "retracted" switch
(S83/5)
Voltage supply and signal voltage |
|
|
N52
16
|
Ignition: ON
Roll bar:
Completely retracted
Extended
|
0-1 V
11-14 V |
Both values not OK:
Roll bar control module (power soft top) (N52).
One value not OK:
17.1. |
17.1 |
|
Resistance |
|
|
N52
16
|
Ignition: OFF
Test cable on N52 disconnected
Roll bar:
Completely retracted
Extended |
0-5
> 20 k
|
Wires.
S83/5.
Values OK:
N52. |
18.0 |
|
RB "extended" limit switch
(S83/6)
Voltage supply and signal voltage |
|
|
N52
34
|
Ignition: ON
Rollover bar:
Extended
Completely retracted |
0-1 V
11-14 V
|
Both values not OK:
N52.
Only one value not OK:
18.1 |
18.1 |
|
Resistance |
|
|
N52
34
|
Ignition: OFF
Test cable on Roll bar control module (power soft top) (N52) disconnected.
Roll bar:
Extended
Completely retracted |
0-5
> 20 k
|
Wiring.
RB "extended" limit switch
(S83/6).
Values OK:
N52.
|
19.0 |
|
RB deployment solenoid (Y57/1)
Resistance |
53 |
N52
|
22
|
Ignition: OFF
Test cable on N52 disconnected. |
approx. 1 |
Wiring
Y57/1.
Value OK
19.1
|
19.1 |
|
Voltage supply from N52 |
52 |
N52
|
22
|
Test cable plugged in to N52.
Ignition: ON
|
11-14 V |
N52. |
20.0 |
|
RB switch (manual operation) (S83)
Voltage supply and signal voltages |
|
|
N52
54
|
Ignition: ON
S83 in rest position.
Operate S83 towards "extend roll bar".
Operate S83 towards "retract roll bar". |
11-14 V
approx. 3 V
0-1 V
|
One value not OK:
S83.
All three values 11-14 V:
Wiring.
S83.
20.1 |
20.1 |
|
Resistances |
|
|
N52
54
|
Ignition: OFF
Test cable on roll bar control module (power soft top) (N52) disconnected.
S83 in rest position.
S83 operated towards "extend rollover bar".
Power soft switch (S84) operated towards "retract rollover bar". |
> 20 k
approx.
250
approx. 1
|
One value not OK:
S83.
Two or three values not OK:
Wiring,
or
S83.
Values OK:
N52. |