Test scope Test connection Test condition Nominal value Possible cause/Remedy
1.0 Voltage supply
Circuit 15


9
N19



7
Ignition: ON
11-14 V

Wiring.
2.0 Ground circuit 31
Resistance





N19

9
Ignition: OFF
Disconnect N19 from .
0

Wiring.

3.0 In-car temperature
sensor (B10/4)
Voltage


9
N19



12
Ignition: ON
Temperature selector:
Red range detent
°C V
20 1.9

Wiring,
B10/4
3.1 In-car temperature
sensor (B10/4)
Resistance


12
N19



2
Ignition: OFF
Disconnect N19 from .
°C k
20 2.1
25 1.7
40 0.9
Wiring,
B10/4
4.0 Icing protection temperature sensor (R35)
Voltage


9
N19



11
Ignition: ON °C V
0 2.0 - 2.4
15 1.4 - 1.8
Wiring,
R35

4.1 Icing protection temperature sensor (R35)
Resistance


11
N19



3
Ignition: OFF
Disconnect N19 from .
°C k
6 3.6
15 2.3
22 1.7
25 1.5
Wiring,
R35

5.0 Activation voltage
Temperature reduction
Voltage


9
N19



2
Ignition: ON
Temperature selector:
From blue range detent

turn temperature selector to red detent stop



>2 V


>3 V
Wiring,
S98s2
5.1 Activation voltage
Temperature increase
Voltage


9
N19



5
Ignition: ON
Temperature selector:
From blue range detent

turn temperature selector to red detent stop



>3 V


>4 V
Wiring,
S98s2
6.0 Actuator motor
Blend air flap actuator motor (M16/8)
Voltage


9
N19



1
Ignition: ON
Temperature selector:
From blue range detent

turn temperature selector to red detent stop



<1V


11-14 V
Wiring,
M16/8

6.1 Actuator motor
Blend air flap actuator motor (M16/8)
Resistance


8
N19



1
Ignition: OFF
Disconnect N19 from .
0.12 k Wiring,
M16/8
7.0 Actuator motor
Blend air flap actuator motor (M16/8)


9
N19



8
Ignition: ON
Temperature selector:
From Red range detent stop

turn temperature selector to blue detent




<1 V


11-14 V
Wiring,
M16/8
8.0 Activation of:
A/C switch (S98s3) to A/C pushbutton control
module (N19)
Voltage


9
N19



10
Ignition: ON
button is illuminated.
Blower stage 4

button is not illuminated, OR
Blower stage= 0


<1 V




11 - 14 V
Wiring,
S98s3
8.1 Activation of:
A/C pushbutton control module (N19) to All Activity Module (N10)
Voltage


9


11
N19





4


4
Ignition: ON
button is illuminated.
Blower stage 4

Insert bridge:
124 589 37 63 00



>3 V

<1 V
Wiring,
N19
9.0 Refrigerant pressure
sensor (B12)

A
B12


B
Disconnect refrigerant pressure sensor connector
Ignition: ON
4.75-5.25 V

Wiring,
B12,
N10
10.0 Outside temperature sensor
(B10/5)
Resistance
(as of 12/99)


3
N19




12
Ignition: OFF
Disconnect N19 from


°C k
20 2.1
25 1.7
40 0.9
50 0.6

Wiring,
B10/5