Left display (DTC) |
Activated flap 3) |
Test condition |
Right display |
Nominal value/Air output |
Test step/Remedy 1) |
|
All |
Press right |
|
No flaps are activated (closed).
All flaps opened (activated). |
32 |
|
Diverter flap 1) |
Press right |
|
Center outlet closed.
Center outlet opened, cold air. |
32 |
|
Diverter flap 1) |
Press right |
|
Center outlet closed.
Center outlet opened, cold air. |
32 |
|
Left blend air flap 1) |
Press right |
|
Left center outlet closed.
Left center outlet, warm air. |
32 |
|
Right blend air flap 1) |
Press right |
|
Right center outlet, closed.
Right center outlet, warm air. |
32 |
|
Left defroster flap long stroke 2) |
Press right |
|
Side defroster leak air.
Side defroster maximum air. |
32 |
|
Left defroster flap long and short stroke 2) |
Pushbutton right |
|
Left defroster outlet closed.
Left defroster outlet opened. |
32 |
|
Right defroster flap, long stroke 3)
|
Pushbutton right |
|
Right defroster flap open, leak air.
Right defroster flap opened. |
32 |
|
Right defroster flap, long and short stroke 3) |
Pushbutton right |
|
Right defroster flap closed.
Right defroster flap opened. |
32 |
|
Main air flap long stroke 4) |
Pushbutton right |
|
Fresh air flow.
Recirculated air 80%. |
32 |
|
Main air flap long and short stroke stroke 4) |
Pushbutton right |
|
Fresh air flow.
Recirculated air 100%. |
32 |
|
Left footwell air flap long stroke 1) |
Pushbutton right |
|
Left footwell air flap closed
Left footwell air flap opened, leak air. |
32 |
|
Left footwell flap, long and short stroke 1) |
Pushbutton right |
|
Left footwell flap, leak air.
Left footwell flap, opened. |
32 |
|
Right footwell flap, long stroke 1) |
Pushbutton right |
|
Right footwell flap, closed.
Right footwell flap opened, leak air |
32 |
|
Right footwell flap, long and short stroke 1) |
Pushbutton right |
|
Right footwell flap, leak air.
Right footwell flap, opened. |
32 |
|
All flaps |
Pushbutton right |
|
No flaps are activated (closed).
All flaps are activated (opened). |
32 |