Diagnostic Manual, Climate Control, Volume 1
Refrigeration System Test Program - Test
Perform Function Test 11 /1.
Charge system with 950 g of refrigerant R134a (test quantity).
Connect gauges to low and high pressure test connections.
Engine at operating temperature.
Center and side air outlets open.
Test period > 3 minutes.
Press .
Vehicle should not be parked in the sun before or during the test.
Electrical wiring diagrams :
Electrical Troubleshooting Manual, Model 202.
|
Conventional tools, test equipment
Description |
Brand, model, etc. |
Multimeter 1) |
Fluke models 23, 83, 85, 87 with thermocouple
Module 80TK |
Manifold gauge set (for R134a only) |
Local purchase |
R134a Recovery/Recycling/Recharging Service Equipment |
Local purchase |
1) Available through the MBUSA Standard Equipment Program. |
|