LOCATION:    3.8 Air Conditioning (A/C)    >   12 Diagnosis - Reading Actual Values (via A/C Pushbutton Control Module [N22])


Diagnosis - Reading Actual Values (via A/C Pushbutton Control Module [N22])



1. The display window will show in sequence the current data from the A/C pushbutton control
module (N22).

2. The temperature control is maintained during the duration
of the test.
 
    P83.40-2028-04

Preparation for Test

1. Ignition: ON

2. Set temperature selection to °F.

3. Press for more than 6 seconds.

4. The left side of the display window will alternately display the number and the in-car temperature (e.g. °F)

5. By pressing + the next highest test step is displayed (see table).

6. Press to end test program.

Note:

The display will, or " " if there is an open circuit, " " if there is a short circuit.



Display code in
N22 window
Possible cause Test step/Remedy 1)
In-car temperature sensor (B10/4) 23 4.0
Outside temperature indicator temperature sensor (B14) 23 10.0
Left heater core temperature sensor (B10/2) 23 7.0
Evaporator temperature sensor (B10/6) 23 5.0
ECT sensor (DFI, IFI) (B11/4) 23 10.0
Refrigerant pressure in bar, e.g. ° corresponds to 6.4 bar (B12) 23 8.0
Refrigerant temperature sensor (B12/1), e.g, ° corresponds to 73.4 ° F 23 6.0
- 2) Not used -
Blower control voltage, e.g. ° (min) - ° (max) corresponds to
0.8 - 6.0 volts
23 20.0
- 2) Control current for auxliary fan e.g. corresponds to 7 mA 23 16.0
Engine speed, e.g. . . (x 100) corresponds to 9900 rpm 23 10.0
Vehicle speed 155 (km/h) 23 10.0
Terminal 58d e.g. corresponds to 99 % battery voltage -
- Battery voltage e.g. 12.5V 23 1.0
3) Software status e.g. -
3) Hardware status e.g. -
2) Version code 1. number code e.g. -
2) Version code 2. number code e.g. benzin (gasoline) -
- not used -
- not used -
- Nominal value (temperature selection) -
A/C compressor emergency shut off e.g. 23 23.0
2) Roof e.g. OPE = open, CLO = closed 23 13.0
2) Left air outlet, potentiometer voltage e.g. V 23 27.0
2) Vacuum actuator 46, feedback potentiometer voltage e.g. V 23 24.0
2) Center air outlet, potentiometer voltage e.g. V 23 28.0
2) Vacuum actuator 47, feedback potentiometer voltage e.g. V 23 25.0
2) Right air outlet, potentiometer voltage e.g. V 23 29.0
2) Vacuum actuator 48, feedback potentiometer voltage e.g. V 23 26.0
1) Observe Preparation for Test.
2) Activate menu.
3) Control module identification.
4) Version coding menu.