Test scope |
Test connection |
Test condition |
Nominal value |
Possible cause/Remedy |
1.0 |
Entire vacuum distributor block |
Connection "P" on vacuum tester. |
Evacuate system with
300 mbar vacuum |
30 mbar
pressure
increase in
1 minute
|
Vacuum distributor block,
1.1 |
1.1 |
Vacuum distributor block,
check valve "a" |
Connection "1" on vacuum tester. |
Evacuate system with
300 mbar vacuum |
30 mbar
pressure
increase in
1 minute
|
Vacuum distributor block,
1.2 |
1.2 |
Vacuum distributor block,
check valve "b" |
Connection "4" on vacuum tester. |
Evacuate system with
300 mbar vacuum |
30 mbar
pressure
increase in
1 minute
|
Vacuum distributor block. |
2.0 |
Vacuum reservoir with
vacuum line |
Red/gray vacuum line (connection 3) on vacuum tester |
Evacuate system with
300 mbar vacuum |
30 mbar
pressure
increase in
1 minute
|
Vacuum lines,
Vacuum reservoir. |
3.0 |
Switchover valve
block (Y11) |
Ignition: OFF
medium green line (connection 5) on vacuum tester |
Evacuate system with
300 mbar vacuum |
30 mbar
pressure
increase in
1 minute
|
Vacuum lines,
Y11 |
|
Test scope |
Test connection |
Test condition |
Nominal value |
Possible cause/Remedy |
1.0 |
Defroster air outlet vacuum actuator, long stroke |
Medium green line on vacuum tester |
Ignition: ON
Press
Evacuate system with
300 mbar vacuum |
30 mbar
pressure
increase in
1 minute
|
Vacuum line,
Vacuum actuator 38 |
1.1 |
Defroster air outlet vacuum actuator, long and short stroke |
Medium green line on vacuum tester |
Ignition: ON
Press
Evacuate system with
300 mbar vacuum |
30 mbar
pressure
increase in
1 minute
|
Vacuum line,
Vacuum actuator 38 |
2.0 |
Diverter valve flap - center air outlet |
Medium green line on vacuum tester |
Ignition: ON
Press
Temperature selector " "
Evacuate system with
300 mbar vacuum |
30 mbar
pressure
increase in
1 minute
|
Vacuum line,
Vacuum actuator 41 |
3.0 |
Blend air flap - center air outlet |
Medium green line on vacuum tester |
Ignition: ON
Press
Evacuate with
300 mbar vacuum |
30 mbar
pressure
increase in
1 minute |
Vacuum line,
Vacuum actuator 45 and 46 |
4.0 |
Footwell flap, long stroke |
Medium green line on vacuum tester |
Ignition: ON
Press
Evacuate system with
300 mbar vacuum |
30 mbar
pressure
increase in
1 minute |
Vacuum line,
Vacuum actuator 39 |
4.1 |
Footwell flap vacuum actuator, long and short stroke. |
Medium green line on vacuum tester |
Ignition: ON
Press
Evacuate system with
300 mbar vacuum |
30 mbar
pressure
increase in
1 minute
|
Vacuum line,
Vacuum actuator 39 |
5.0 |
Fresh/recirculating air flap vacuum actuator. |
Medium green line on vacuum tester |
Ignition: ON
Illuminates
Evacuate system with
300 mbar vacuum |
30 mbar
pressure
increase in
1 minute
|
Vacuum line,
Vacuum actuator 42 |
6.0 |
Left air outlet vacuum actuator. |
Medium green line on vacuum tester |
Ignition: ON
Left side air outlet adjuster closed.
Evacuate system with
300 mbar vacuum
|
30 mbar
pressure
increase in
1 minute
|
Vacuum line,
Vacuum actuator 46 |
7.0 |
Center air outlet vacuum actuator. |
Medium green line on vacuum tester |
Ignition: ON
Center air outlet adjuster closed.
Evacuate system with
300 mbar vacuum
|
30 mbar
pressure
increase in
1 minute
|
Vacuum line,
Vacuum actuator 47. |
8.0 |
Right side air outlet vacuum actuator. |
Medium green line on vacuum tester |
Ignition: ON
Right side air outlet adjuster closed.
Evacuate system with
300 mbar vacuum
|
30 mbar
pressure
increase in
1 minute
|
Vacuum line,
Vacuum actuator 48 |
9.0 |
Center air outlet,
"Cold" pushbutton |
Medium green line on vacuum tester |
Ignition: ON
"Cold" function indicator lamp in "cold" pushbutton (blue) illuminates.
Evacuate system with
300 mbar vacuum
|
30 mbar
pressure
increase in
1 minute
|
Vacuum line,
Vacuum actuator 41 |
10.0 |
Center air outlet,
"Warm" pushbutton |
Medium green line on vacuum tester |
Ignition: ON
"Warm" function indicator lamp in "warm" pushbutton (red) illuminates.
Evacuate system with
300 mbar vacuum
|
30 mbar
pressure
increase in
1 minute
|
Vacuum line,
Vacuum actuator 45 |