LOCATION:    A CFI Test and Adjustment Data    >   12 Engine 102.961 CFI


Engine 102.961 CFI

Engine 102.961
CFI system designation 2
On-off ratio/DTC readout (CFI)
On-off ratio readout with ignition: ON
Engine coolant temperature >80°C %
Engine coolant temperature <70°C %



-
-
Current at EHA
Ignition: ON mA
After start enrichment and warmup
After start enrichment at +20 °C engine coolant temperature mA
Warmup base value at+20°C engine coolant temperature mA
Engine coolant temperature +80°C mA
Enrichment during acceleration and at
+20°C engine coolant temperature mA
Engine at operating temperature
Part load mixture correction mA
Wide open throttle enrichment at 2000 rpm mA
Deceleration fuel shut off approx. mA

75 - 85 1)

20 - 28
11 - 15
7 - 9

>15

readout oscillates
7 - 9
-60
1) Connector on engine coolant temperature sensor disconnected.

Engine 102.961
CFI system designation 2
Ignition timing and dwell
Closed throttle (idle) speed rpm
Ignition timing with vacuum BTDC

Engine speed rpm
Ignition timing without vacuum BTDC
Dwell °
Dwell %

800±50
5

4500
14 - 18 2)
27 - 54
30 - 60
2) Starting 1984 24-28 oCKA BTDC

Engine 102.961
CFI system designation 2
Closed throttle ( idle)
Selector lever position/Transmission range
Engine oil temperature °C approx.
Closed throttle (idle) speed rpm
Control range %
°

P/N D
80 80
850±50 <850
25 - 31 <28
22 - 28
Vacuum mbar
Lambda control ontrol range %
550 - 650
2.1 - 4.8 V 3)
3) Disconnect oxygen sensor connector. Read control value (Volt). Readout must not oscillate. Reconnect oxygen sensor connector, readout oscillates.
Test value must not deviate more than ±0.8 Volt from the control value.

Engine 102.961
CFI system designation 2
Engine performance 4)

Engine speed rpm
Output, manual transmission, 3rd gear hp
Output, 4-speed AT, transmission range 3 hp


5200
88
83
4) These are minimum performance values. Do not exceed speed of 80 mph.

Check performance only at simulated engine coolant temperature of 80 oC (use 2 resistance substitution units)