Diagnosis - Complaint Related Diagnostic Chart

Complaint/Problem Possible cause Test step/Remedy 1)
D2B Ring-Loop does not come-up (energize). Voltage supply to one of the D2B components not ensured.
(Voltage is used to check for voltage supply to D2B ring-Loop components). A "Diagnosis Wake Up Call" can only be used when there is an interruption within the D2B Ring-Loop.
Perform Diagnosis Wake Up Call.
D2B Ring-Loop does not come-up (energize). The D2B connectors are improperly connected or are dirty.
Clean and properly reconnect all D2B connections.
D2B Ring-Loop does not come-up (energize) and there are no concrete indications in the DTC memory as to where the fault lies within the D2B Ring-Loop. Fiber optic cable defect.
Check all the fiber optic cables beginning in a clock-wise direction (Information flow pattern) starting at the radio or COMAND unit. Also see 20
D2B Ring-Loop does not come-up (energize) and there are no concrete indications in the DTC memory as to where the fault lies within the D2B Ring-Loop. Transmitter unit of a control module is defective.
Receiver unit of a control module is defective.
Check all the fiber optic cables beginning in a clock-wise direction (Information flow pattern) starting at the radio or COMAND unit. Also see 20