Instrument Cluster
| Complaint/Problem |
Possible cause |
Remedy/Test step 1) |
| Entire instrument cluster (A1) not functioning. |
Power supply,
Instrument cluster (A1) |
up to 08/95 23 1.0
as of 09/95 24 1.0 |
| Indicator lamps for ABS, ASR, charge control, brake pad wear, brake fluid, parking brake and ADS are not functioning. |
Power supply,
Instrument cluster (A1) |
up to 08/95 23 1.0
as of 09/95 24 1.0 |
| Rhythmic blinking of warning and indicator lamps in one second intervals |
Short circuit in instrument cluster (A1). |
up to 08/95 23 1.0
as of 09/95 24 1.0 |
| Non rhythmic blinking of warning and indicator lamps |
Low voltage at instrument cluster (A1). |
up to 08/95 23 1.0
as of 09/95 24 1.0 |
| Instrument cluster illumination not operating. |
Bulbs,
Exterior lamp switch (S1),
Instrument cluster (A1). |
up to 08/95 23 2.0
as of 09/95 24 2.0 |
| Warning lamps for ABS, ETS/ASR/ESP brake pad wear, brake fluid/parking brake do not go out after engine is started. |
Instrument cluster (A1).
Traction system control module (N47) |
as of 09/95 24 3.0 |
| Fuel tank gauge (A1p2) inaccurate or not operating. |
Instrument cluster (A1),
Fuel level sensor (B4). |
up to 08/95 23 3.0
as of 09/95 24 4.0 |
| Fuel consumption gauge (A1p10) inaccurate or not operating. |
Instrument cluster (A1),
Fuel consumption signal from LH-SFI, HFM-SFI, ME-SFI control module |
up to 08/95 23 4.0
as of 09/95 24 5.0 |
| Engine oil pressure gauge (A1p3) inaccurate or not operating. |
Oil pressure sensor (B5),
Instrument cluster (A1). |
up to 08/95 23 5.0
as of 09/95 24 6.0 |
| Tachometer (A1p5) inaccurate or not operating. |
Instrument cluster (A1),
TN-signal. |
up to 08/95 23 6.0
as of 09/95 24 7.0 |
| Low engine oil level indicator lamp (A1e12) lights up but oil level is OK. |
Oil level switch S43.
|
up to 08/95 23 7.0
as of 09/95 24 8.0 |
| Electronic speedometer (A1p8) inaccurate or not operating. |
Instrument cluster (A1),
Transmission inductive speed sensor (L2),
Vehicle speed signal from traction system control
module (N47) |
up to 08/95 23 8.0
as of 09/95 24 9.0 |
| Outside temperature display (A1p4) inaccurate or not operating. |
Instrument cluster (A1),
Outside temperature indicator temperature sensor (B14). |
up to 08/95 23 9.0
as of 09/95 24 10.0 |
| ECT gauge (A1p1) inaccurate or not operating. |
Instrument cluster (A1),
ECT gauge sensor (B13) |
up to 08/95 23 10.0
as of 09/95 24 11.0 |