Diagnostic Manual, Info./Comm., Volume 1
Electrical Test Program - Audio Switchover Test
|
Test scope |
Test connection |
Test condition |
Nominal value |
Possible cause/Remedy |
1.0 |
Audio switchover
NAM programming |
|
|
|
Ignition: ON
Radio: ON
CTEL: ON
Known good service area.
Verfiy NAM option programming (data step 8 of programming guide)
Model 129=1110
Model 140=1100
Enter 611
Press SEND |
Radio mutes |
1.1
Note:
The radio will not mute during incoming calls unless Incoming Mute is activated in the second menu. |
1.1 |
Control voltage |
|
|
A2/4
4
|
Disconnect 5-pole connector on back of radio.
Enter 611
Press SEND |
< 1 V |
Nominal value OK: 1.2
Nominal value not OK: 1.3 |
1.2 |
Radio |
|
|
|
Radio: ON
CTEL: OFF
Disconnect 5-pole connector on back of radio.
Momentarily ground pin 4 on back of radio. |
Radio mutes and is indicated in radio display. |
Nominal value OK: 1.3
Nominal value not OK: Replace radio |
1.3 |
Wiring |
A35
2 |
|
A2/4
4
|
Disconnect 5-pole connector on back of radio.
Disconnect connector 2 from A35.
|
< 1 |
Nominal value OK: 27
Nominal value not OK: Wiring |
|