B. DTC readout with permanent and intermittent faults   
            
            
              | Diagnostic Trouble Code (DTC) | Possible Cause | Test Step/Remedy 1) | 
            
              |     | No stored DTC's in system memory | - | 
            
              |     | In - car temperature sensor (B10/4), short circuit |  23  1.0 | 
            
              |     | In - car temperature sensor (B10/4), open circuit |  23  1.0 | 
            
              |     | Outside temperature sensor (B10/5), short circuit |  23  2.0 | 
            
              |     | Outside temperature sensor (B10/5), open circuit |  23  2.0 | 
            
              |     | Evaporator temperature sensor (B10/6), short circuit |  23  3.0 | 
            
              |     | Evaporator temperature sensor (B10/6), open circuit |  23  3.0 | 
            
              |     | Heater core temperature sensor (B10/1), short circuit |  23  4.0 | 
            
              |     | Heater core temperature sensor (B10/1), open circuit |  23  4.0 | 
            
              |     | ECT sensor (B10/8), short circuit |  23  5.0 | 
            
              |     | ECT sensor (B10/8), open circuit |  23  5.0 | 
            
              |     | Center air outlet adjuster (N18/2r2), short circuit |  23  7.0 | 
            
              |     | Center air outlet adjuster (N18/2r2), open circuit |  23  7.0 | 
            
              |     | Center air outlet feedback potentiometer (R23/3), short circuit |  23  12.0 | 
            
              |     | Center air outlet feedback potentiometer (R23/3), open circuit |  23  12.0 | 
            
              |     | Left air outlet adjuster (N18/2r1), short circuit |  23  6.0 | 
            
              |     | Left air outlet adjuster (N18/2r1), open circuit |  23  6.0 | 
            
              |     | Left air outlet feedback potentiometer (R23/1), short circuit |  23  11.0 | 
            
              |     | Left air outlet feedback potentiometer (R23/1), open circuit |  23  11.0 | 
            
              |     | Right air outlet adjuster (N18/2r3), short circuit |  23  8.0 | 
            
              |     | Right air outlet adjuster (N18/2r3), open circuit |  23  8.0 | 
            
              |     | Right air outlet feedback potentiometer (R23/2), short circuit |  23  13.0 | 
            
              |     | Right air outlet feedback potentiometer (R23/2), open circuit |  23  13.0 | 
            
              |     | Auxiliary coolant pump (M13), short circuit |  23  20.0 | 
            
              |     | Automatic A/C monovalve (Y19), short circuit |  23  19.0 | 
            
              |     | A/C compressor signal, short circuit |  23  25.0 | 
            
              |     | Auxiliary fan signal, 2nd stage, short circuit |  23  24.0 | 
            
              |     | Auxiliary fan signal, 1st stage, short circuit |  23  23.0 | 
            
              |     | Not used | - | 
            
              |     | Switchover valve block (Y11), short circuit |  23  21.0 | 
            
              |     | Auxiliary coolant pump (M13), open circuit |  23  20.0 | 
            
              |     | Automatic A/C monovalve (Y19), open circuit |  23  15.0 | 
            
              |     | A/C compressor signal, open circuit |  23  25.0 | 
            
              |     | Auxiliary fan signal, 2nd stage, open circuit |  23  24.0 | 
            
              |     | Auxiliary fan signal, 1st stage, open circuit |  23  23.0 |