    Diagnostic Manual, Info./Comm., Volume 1 
    
    
    
    
    
    Electrical Test Program - Audio Switchover Test 
    
    
      
        | 
            
              |   | Test scope | Test connection | Test condition | Nominal value | Possible cause/Remedy |  
              | 1.0 | Audio switchover NAM programming
 |       |       |       | Ignition: ON Radio: ON
 CTEL: ON
 Known good service area.
 Verfiy NAM option programming (data step 8 of programming guide)
 Model 129=1110
 Model 140=1100
 
 Enter 611
 Press SEND
 | Radio mutes |  1.1 
 Note:
 The radio will not mute during incoming calls unless Incoming Mute  is activated in the second menu.
 |  
              | 1.1 | Control voltage | 
   |  | A2/4    4 
                 | Disconnect 5-pole connector on back of radio. Enter 611
 Press SEND
 | < 1 V | Nominal value OK:  1.2 
 Nominal value not OK:
  1.3 |  
              | 1.2 | Radio |       |       |       | Radio: ON CTEL: OFF
 Disconnect 5-pole connector on back of radio.
 Momentarily ground pin 4 on back of radio.
 | Radio mutes and      is indicated in radio display. | Nominal value OK:  1.3 
 Nominal value not OK:
  Replace radio |  
              | 1.3 | Wiring | A35 2
   |  | A2/4    4 
                 | Disconnect 5-pole connector on back of radio. Disconnect connector 2 from A35.
 
 | < 1   | Nominal value OK:  27 
 Nominal value not OK: Wiring
 |  
            
         |