Diagnostic Manual, Body and Accessories,
Volume 1.1
Electrical Test Program - Test (Backup Assist)
Test step |
Test scope |
Test connection |
Test condition |
Nominal value |
Possible cause/Remedy |
1.0 |
Starter lock-out/backup lamp switch
(S16/1) |
21
|
A37
|
20
|
Ignition: ON
Selector lever position: N |
<1 V |
Wiring,
1.1,
PSE control module (A37 or A37/1).
|
|
|
|
|
|
Selector lever position: R |
11 - 14 V |
Wiring,
1.1,
A37 or A37/1.
|
1.1 |
S16/1 |
21
|
A37
|
20
|
Disconnect PSE control module (A37
or A37/1)
from
Ignition: ON
Selector lever position: N |
<1 V |
Wiring,
S16/1.
|
|
|
|
|
|
Selector lever position: R |
11 - 14 V |
Wiring,
S16/1.
|
|