Diagnostic Manual, Body and Accessories,
Volume 1.1
Electrical Test Program - Preparation for Test (CL)
Preliminary work:
Diagnosis - Diagnostic Trouble Code (DTC) Memory
11 PSE
|
Preparation for Test:
1. Check fuse F2-5, F4-3 and fuse F4-11.
2. Provide access to PSE control module (A37, A37/1).
3. Disconnect convenience feature (CF) control module (N57), anti-theft
alarm (ATA) control module (N26), infrared remote central locking (IRCL)
control module (N54).
4. Connect socket box with test cable according to connection diagram,
see Figure 1.
Electrical wiring diagrams
See Electrical Troubleshooting Manual, Model 140, Volume 2. |
Equipment
Multimeter 1) |
Fluke models 23, 83, 85, 87 |
1) Available through the
MBUSA Standard Equipment Program. |
|