Diagnostic Manual, Body and Accessories,
Volume 1.1
Diagnosis - Function Test (Orthopedic Seat Backrest)
Preparation for Test
1. Check fuse F4-3 and fuse F4-11.
2. Battery voltage 11 - 14 V.
3. Ignition: ON |
Test step/Test
scope |
Test condition |
Nominal value |
Possible cause/Remedy
1) |
1.0 Changing backrest contour
in X-direction (intensity) |
Turn adjuster slowly from position
0 to position 5 at least 5 times. Sit in seat. |
Backrest must change shape noticeably
in lumbar area. |
Backrest does not change shape and
pump motor in PSE control module (A37, A37/1) does not run.
23 PSE 1.0,
PSE control module (A37, A37/1).
Backrest does not change shape even though pump motor in PSE control module
(A37, A37/1) runs.
32 PSE 7.0,
32
3.0.
|
1) Observe Preparation
for Test, see
22. |
Preparation for Test
1. Check fuse F4-3 and fuse F4-11.
2. Battery voltage 11 - 14 V.
3. Ignition: ON |
Test step/Test
scope |
Test condition |
Nominal value |
Possible cause/Remedy
1) |
2.0 Changing backrest contour
in Z-direction (height) |
Adjuster in position 5.
In sequence select the three height adjust buttons. Sit in seat. |
Backrest must change shape noticeably
in lumbar area. |
Backrest does not change shape and
pump motor in PSE control module (A37, A37/1) does not run.
23 PSE 1.0,
PSE control module (A37, A37/1).
Backrest does not change shape even though pump motor in PSE control module
(A37, A37/1) runs.
32 PSE 7.0,
32
4.0.
|
2.1 Changing backrest contour in
X-direction (intensity) |
Turn adjuster slowly from position
0 to position 5 at least 5 times. Sit in seat. |
Backrest must change shape noticeably
in lumbar area. |
Backrest does not change shape and
pump motor in PSE control module (A37, A37/1) does not run.
23 PSE 1.0,
PSE control module (A37, A37/1).
|
2.2 Changing backrest contour side
bolster pressure |
Use side bolster rocker switch to
change pressure from minimum to maximum 5 times. Sit in seat. |
Backrest must change shape noticeably
in side bolster area. |
Backrest does not change shape even though pump motor in PSE
control module (A37, A37/1) runs.
,
32 4.0.
|
1) Observe Preparation
for Test, see
22. |
|