Home
Diagnostic Manual, Body and Accessories,
Volume 1.1

 Printable version
LOCATION:    3.1 Model 140  Pneumatic System Equipment (PSE) >   22 Electrical Test Program - Preparation for Test (Retractable Trunk Lid Grip)


Electrical Test Program - Preparation for Test (Retractable Trunk Lid Grip)

Preliminary work:
Diagnosis - Diagnostic Trouble Code (DTC) Memory 11 PSE (3.1)

Preparation for Test:
1. Check fuse F4-3 and fuse F4-11.
2. Provide access to PSE control module (A37, A37/1).
3. Disconnect anti-theft alarm (ATA) control module (N26), infrared remote central locking (IRCL) control module (N54).
4. Connect socket box with test cable according to connection diagram, see 22 Fig.1.

Electrical wiring diagrams
See Electrical Troubleshooting Manual, Model 140, Volume 2.

Equipment

Multimeter 1) Fluke models 23, 83, 85, 87
1) Available through the MBUSA Standard Equipment Program.