Diagnostic Manual, Body and Accessories,
Volume 1.1
Electrical Test Program - Preparation for Test (Retractable Trunk Lid Grip)
Preliminary work:
Diagnosis - Diagnostic Trouble Code (DTC) Memory
11 PSE (3.1)
|
Preparation for Test:
1. Check fuse F4-3 and fuse F4-11.
2. Provide access to PSE control module (A37, A37/1).
3. Disconnect anti-theft alarm (ATA) control module (N26), infrared remote
central locking (IRCL) control module (N54).
4. Connect socket box with test cable according to connection diagram, see
22 Fig.1.
Electrical wiring diagrams
See Electrical Troubleshooting Manual, Model 140, Volume 2. |
Equipment
Multimeter 1) |
Fluke models 23, 83, 85, 87 |
1) Available through the