Home
Diagnostic Manual, Body and Accessories,
Volume 1.1

 Printable version
LOCATION:    3.2 Model 202  Pneumatic System Equipment (PSE) >   22 Electrical Test Program - Preparation for Test (Central Locking)


Electrical Test Program - Preparation for Test (Central Locking)

Preparation for Test:
1. Model 202 up to 11/94: Check fuse F3-33 ok,
2. Model 202 as of 12/94: Check fuse F1-27 ok,
3. Provide access to PSE control module (A37/4, A37/5).
4. Connect socket box with test cable according to connection diagram, see 22, Figure 1.


Electrical Wiring Diagrams
See Electrical Troubleshooting Manual, Model 202, Volume 2, group 80

Conventional tools, test equipment

Description Brand, model, etc.
Multimeter 1) Fluke models 23, 83, 85, 87
1) Available through the MBUSA Standard Equipment Program.