Diagnostic Manual, Body and Accessories,
Volume 1.1
Electrical Test Program - Test
 |
Test scope |
Test connection |
Test condition |
Nominal value |
Possible cause/Remedy |
1.0 |
Remote trunk release |
|
|
|
Trunk lid closed.
Trunk lid not locked with mechanical key.
Remote trunk release switch (S15):
Press switch: |
Trunk lid opens.
|
Wiring,
1.1,
2.0,
23 PSE
1.0,
32
1.0,
32 PSE
2.0,
PSE control module (A37).
|
1.1 |
Remote trunk release
switch (S15) |
10
(A.2)
|
A37
|
 8
(C.8)
|
Disconnect PSE control module (A37)
from .
S15:
Rest position
S15:
Hold pressed |
< 1 V
11 - 14 V
|
Wiring,
S15 |
2.0 |
Activate RTR control
valve (Y65/3) (CL) |
2
(C.2) |
A37
|
 11
(A.3)
|
S15:
Rest position
S15:
Hold pressed
|
< 1 V
11 - 14 V, as long as PSE pump runs (use fluke 83, 88 to measure voltage).
|
Wiring,
1.1,
23 PSE
1.0,