Test scope |
Test connection |
Test condition |
Nominal value |
Possible cause/Remedy |
1.0 |
Central locking system
Vacuum supply |
PSE control module
connector CL to black connector on tester. |
Cap connections on the PSE
control module:
Bosch: RHR, MVA
Close front doors.
Lock vehicle using interior switch (CL).
|
450
mbar in 1.2 sec. |
23 PSE/CL 1.0 |
2.0 |
Central locking system
Pressure supply |
PSE control module
connector CL to yellow connector on tester. |
Cap connections on the PSE
control module:
Bosch: RHR, MVA
Close front doors.
Unlock vehicle using interior switch (CL).
|
450
mbar in 0.8 s |
23 PSE/CL 1.0 |
3.0 |
Multi-contour seat
Pressure supply
(model 210 only) |
PSE control module
connector OL to yellow connector on tester. |
Cap connections on the PSE
control module:
RHR, KLA, CL
Turn ignition OFF, ON |
Pump runs after approx. 4
sec. delay.
450 mbar in 0.8
s
|
2.1
23
1.0-3.0
PSE control module (A37),
Combination control
module (N10-1). |
4.0 |
Retractable rear head
restraints
Vacuum supply
(model 210 only) |
PSE control module
connector RHR to black connector on tester. |
Cap connections on the PSE
control module:
Bosch: CL, MVA
Retractable rear head restraints up.
Ignition: ON
Press RHR unlocking switch
|
450
mbar in 1.2 s |
23 PSE/RHR
1.0 |
5.0 |
Manifold vacuum assist
Vacuum supply
(model 210 only) |
PSE control module
connector KLA or MVA to black connector on tester. |
Cap connections on the PSE
control module:
Bosch: RHR, CL
Turn ignition OFF, ON |
Pump runs after approx. 8
sec. delay.
450 mbar in 1.2
s
|
2.1
23
1.0-3.0
PSE control module (A37),
Combination control
module (N10-1). |
6.0 |
Remote trunk release
Pressure supply
(model 210 only) |
PSE control module
connector CL to yellow connector on tester. |
Cap connections on the PSE
control module:
Bosch: RHR, MVA
With vehicle unlocked, press remote trunk release button.
|
450
mbar in 1.2 s |
23 PSE/RTR
1.0 |
7.0 |
Central locking
Safety switch time |
- |
Cap connections on the PSE
control module:
Bosch: RHR, MVA
Close front doors.
Unlock vehicle using interior switch (CL).
|
Pump runs 10±1
sec. |
23 PSE/CL 1.0,
PSE control module (A37). |
8.0 |
Additional Consumers
Safety switch time |
- |
Cap connections on the PSE
control module:
Bosch: CL, MVA
Turn Ignition: ON
Press RHR button.
|
Pump runs
60 sec. |
23 PSE/RTR
1.0-8.0,
2.1
23 1.0-3.0,
Combination control
module (N10-1). |