Diagnostic Manual, Climate Control, Volume 1
Diagnosis - Function Test
|
Test step/Test sequence |
Test condition |
Nominal value |
Possible cause/Remedy 1) |
1.0 Defrost |
Temperature selector wheel in "white range".
button indicator lamp is not illuminated.
Air distribution dial set at 12 o'clock position (vertical). |
Air venting from center vents.
Air venting from defroster outlets.
A/C compressor engaged. |
23 ,
32 1.0 - 3.0
|
2.0 Normal ventilation in regulating mode |
Temperature selector wheel in "white range".
button indicator lamp is not illuminated.
Air distribution dial set at 4 o'clock position. |
Air venting from lower and upper outlets.
A/C compressor engaged.
Tempered air from center air outlet.
Duovalve cycles at the same time and coolant circulation pump (M13) runs. |
23 11.0 , 12.0 , 14.0 , 15.0 , 16.0 , 17.0 , 18.0
|
3.0 Economy setting not in heating mode |
Temperature selector wheel in "blue range" detent.
button indicator lamp is illuminated.
Air distribution dial set at 9 o'clock position. |
Air venting from center air outlets (ambient temperature)
A/C compressor not engaged. |
23 11.0 , 14.0 , 15.0
|
4.0 Economy setting in heating mode |
Temperature selector wheel in "red range" detent.
button indicator lamp is illuminated.
Air distribution dial set at 4 o'clock position. |
Heated air venting from lower, upper and center air outlets.
A/C compressor not engaged.
|
23 11.0 , 14.0 , 15.0
|
5.0 "REST" (residual engine heat utilization mode) |
Ignition: OFF
Press button.
Temperature selector wheel in "red range".
Air distribution dial set at 4 o'clock position. |
Heated air venting from lower, upper and center air outlets.
|
23 12.0 , 14.0 , 15.0
|
6.0 "A/C" Test |
See A/C Test section. |
|
51 , 52
|
7.0 Quality Control and Heater Output Test |
See Quality Control and Heater Output Test section. |
Special tools |
51 ,
52
22 |
1) Observe Preparation for Test, see 22 . |
|