Test scope |
Test connection |
Test condition |
Nominal value |
Possible cause/Remedy |
1.0 |
Entire vacuum distributor block,
See 32 /1 |
Connection "P" on vacuum tester. |
Evacuate system with
300 mbar vacuum.
|
30 mbar pressure increase in
1 minute.
|
Vacuum distributor block,
1.1 |
1.1 |
Vacuum distributor block,
Check valve "a" |
Connection "1" on vacuum tester. |
Evacuate system with
300 mbar vacuum.
|
30 mbar pressure increase in
1 minute.
|
Vacuum distributor block,
1.2 |
1.2 |
Vacuum distributor block,
Check valve "b" |
Connection "4" on vacuum tester. |
Evacuate system with
300 mbar vacuum. |
30 mbar pressure increase in
1 minute
|
Vacuum distributor block. |
2.0 |
Vacuum reservoir with vacuum line,
See 32 /1 |
Red/gray line
(connection 3) on vacuum tester. |
Evacuate system with
300 mbar vacuum.
|
30 mbar pressure increase in
1 minute
|
Vacuum lines,
Vacuum reservoir. |
3.0 |
Fresh/recirculated air flap switchover valve (Y13),
See 32 /4, (Figure 2) |
Ignition: OFF
Medium green line (connection 2) on vacuum tester. |
Evacuate system with
300 mbar vacuum.
|
30 mbar pressure increase in
1 minute
|
Vacuum lines,
Y13 |
4.0 |
Fresh/recirculated air flap vacuum actuator,
See 32 /4, (Figure 2, 44) |
|
Evacuate system with
300 mbar vacuum.
|
30 mbar pressure increase in
1 minute
|
Vacuum lines,
Actuator. |