    Diagnostic Manual, Climate Control, Volume 1 
    
    
    
    
    
    Pneumatic Test Program - Test 
    
    
      
        | 
            
              | Preparation for Test 
 1.  Review
  11 ,  20 ,  21 ,  22 ,  31 ,  32 ,  41 , 
 2. Check gray vacuum line to intake manifold for leaks.
 
 
   Permissible leakage of the elements with vacuum lines at 400 mbar vacuum per minute is
  30 mbar. 
 Parts Required for Test:
 1 Connector 129 800 95 15
 
 
 |  
           
           
           
           
           
           
            
              |   | Test scope | Test connection | Test condition | Nominal value | Possible cause/Remedy |  
              | 1.0 | Fresh/recirculating air flap vacuum actuator, (see Figure 1, 44)
 |  |  button illuminated. Evacuate system with
 300 mbar vacuum
 |  30 mbar pressure increase in 1 minute
 
 | Vacuum lines, Fresh/recirculating air flap vacuum actuator.
 |  
            
         |