Diagnostic Manual, Climate Control, Volume 1
Pneumatic Test Program - Test
Preparation for Test
1. Review 11 , 20 , 21 , 22 , 31 , 32 , 41 ,
2. Check gray vacuum line to intake manifold for leaks.
Permissible leakage of the elements with vacuum lines at 400 mbar vacuum per minute is 30 mbar.
Parts Required for Test:
1 Connector 129 800 95 15
|
|
Test scope |
Test connection |
Test condition |
Nominal value |
Possible cause/Remedy |
1.0 |
Fresh/recirculating air flap vacuum actuator,
(see Figure 1, 44) |
|
button illuminated.
Evacuate system with
300 mbar vacuum |
30 mbar pressure increase in
1 minute
|
Vacuum lines,
Fresh/recirculating air flap vacuum actuator. |
|