Diagnostic Manual, Climate Control, Volume 1
Diagnosis - Reading Actual Values - via Hand-Held tester (HHT)
Test step/Test sequence
|
Test condition |
Nominal value |
Possible cause/Remedy 1) |
Circuit 30 |
|
|
Wiring,
Battery.
|
Engine temperature |
Ignition: ON
Start engine and bring to operating temperature.
|
Operating temperature approx. ° |
Wiring,
ECT sensor (B11/4),
All Activity Module (AAM) (N10). |
Outside air temperature |
Ignition: ON |
Based on yearly season,
approx. ° |
Wiring,
Outside temperature indicator temperature sensor (B14),
All Activity Module (AAM) (N10).
|
Blower relay (F1k21)
Voltage supply |
Ignition: ON
Blower set to stage 4 |
|
Wiring,
F1k21,
Blower motor (M2),
All Activity Module (AAM) (N10).
|
Engine cooling fan stage 1
relay (F1k26)
|
Ignition: ON |
|
Wiring,
F1k26,
Auxiliary fan (M4),
All Activity Module (AAM) (N10). |
Circulation pump relay (F1k19) |
Ignition: ON |
|
Wiring,
F1k19,
Coolant circulation pump (M13),
All Activity Module (AAM) (N10).
|
Refrigerant pressure |
Start engine.
button is illuminated.
Blower motor set to stage 4
|
|
23 9.0 |
A/C compressor (A9) |
Start engine.
button is illuminated.
Blower motor set to stage 4
|
|
23 8.0 ,
All Activity Module (AAM) (N10),
A9 |
Activate A/C system |
Ignition: ON |
|
Wiring,
A/C pushbutton control module (N19),
All Activity Module (AAM) (N10)
|
|