Operation No. of Text Description and Time
Allowance 27-0035 or 27-0037 or 27-0038

Test Conditions

1 Vacuum tester (019) on vacuum control valve (65) with Y-fitting connect, disconnect
2 Run engine at CTP : Vacuum > 400 mbar
3 Turn engine off, move throttle linkage to full load 0 mbar
4 Vacuum control valve adjust by loosening nuts (65/1), move throttle linkage to full load position and turn vacuum control valve clockwise against throttle linkage. Tighten nuts (65/1).

Special Tools