Diagnostic Manual, Info./Comm., Volume 1
Electrical Test Program - Preparation for Test
1. Ignition: ON
2. Read out actual values and perform activations using the HHT
3. Ignition: OFF
4. Connect socket box and test cable according to connection diagram
(Figure 1)
Note:
Use recommended multimeter (refer to 22 /2) equipped with an analog bar graph display.
5. After completing repairs on the PTS:
Erase DTC's
Wait 20 seconds (the existing fault[s] will be erased after 20 seconds).
Electrical wiring diagrams:
Electrical Trouble Shooting Manual (ETM) Model 140 and 210
Note:
When replacing the Ultrasonic PTS control module (N62), the control module must be version coded using the HHT. Follow instruction as indicated in the HHT display.
|
Conventional tools, test equipment
Description |
Brand, model, etc. |
Multimeter 1) |
Fluke models 2) 23, 83, 88 |
1) Available through the MBUSA Standard Service Equipment Program.
2) Only multimeters with analog display can be used |
|