Preparation for Test:
1. Battery voltage 11 - 14 V,
2. Check fuses ok,
3. Voltage to control modules and CAN data lines ok,
3. Ignition: ON
|
Test step/Test
scope |
Test condition |
Nominal value |
Possible cause/Remedy
1) |
1.0 Changing backrest contour in
X-direction (intensity of lower and upper air cushion). |
Turn pressure adjuster for upper
or lower air cushion slowly from minmum to maximum at least 5 times. |
Backrest must change shape noticeably
in lumbar support area. |
Backrest does not change shape and
pump motor in PSE control module (A37) does not run.
PSE version coding incorrect,
PSE (A37).
Backrest does not change shape even though pump motor in PSE control module
(A37/5) runs.
32 PSE/OSB
1.0,
32 PSE/OSB
2.0,
33 PSE 7.0
|
2.0 Changing backrest contour side
bolster. |
Use side bolster rocker switch to
change pressure from minimum to maximum 5 times. |
Backrest must change shape noticeably
in lumbar support area. |
Backrest does not change shape and
pump motor in PSE control module (A37) does not run.
PSE version coding incorrect,
PSE (A37).
Backrest does not change shape even though pump motor in PSE control module
(A37/5) runs.
32 PSE/OSB
3.0,
33 PSE 7.0
|
3.0 Changing seat bottom cushion
length. |
Turn pressure adjuster for seat bottom
cushion from minmum to maximum 5 times. |
Seat cushion length must change noticeably. |
Backrest does not change shape and
pump motor in PSE control module (A37) does not run.
PSE version coding incorrect,
PSE (A37).
Backrest does not change shape even though pump motor in PSE control module
(A37/5) runs.
32 PSE/OSB
4.0,
33 PSE 7.0
|
1) Observe Preparation
for Test, see
22. |
|