Diagnostic Manual, Body and Accessories,
Volume 1.1
Pneumatic Test Program - Test (MVA)
Preliminary work:
PSE control module voltage supply
23 PSE 1.0,
2.0
PSE Control Module Test
32 PSE |
Data (mbar)
Test procedure |
Permissible deviation |
Allowable leakage of pneumatic lines
and vacuum distribution blockat 300 mbar vacuum in 1 minute. |
30
mbar |
Allowable leakage of vacuum distribution
block with line at 300 mbar vacuum
in 1 minute. |
25
mbar |
|
Preparation for Test:
1. Provide access to PSE control module (A37), disconnect transparent
MVA pneumatic line with socket from PSE control module.
2. Connect tester to bottom side of pneumatic multiple connector at
SRU (MVA) using connector 202 805 03 44.
3. Connect tester to disconnected pneumatic line using connector
202 805 03 44.
4. Provide access to vacuum distribution block in right component compartment
and pry off all pneumatic lines except transparent
MVA line at connection 1.
If no leakage is found during test of MVA, check any connected pneumatic
systems for leaks as well.
Parts Required for Test:
1 Connector 202 805 03 44
1 Rubber hose, 50 mm long 007 997 61 82
2 Connector 124 805 02 44
1 Cap 000 987 11 45
Note:
The connections on the PSE control module and pneumatic multiple connector
are marked with their German acronyms. In other words:
ZV (German) = CL (English),
SRU (German) = MVA (English),
OSL (German) = OSB (English).
|
|
Test scope |
Test connection |
Test condition |
Nominal value |
Possible cause/Remedy |
1.0 |
Pneumatic line |
Black connector on tester
to connector.
|
Apply 300 mbar vacuum to entire system. |
Vacuum loss
30 mbar in
1 minute. |
32 PSE/MVA
2.0,
32 PSE/MVA
3.0 |
Preparation for Test:
1. Provide access to vacuum distribution block.
2. Disconnect pneumatic lines at vacuum distribution block.
3. Connect tester to white pneumatic line (pneumatic connector #
6).
4. Connect tester to one end of pneumatic line (s) and plug other end with
cap, part no. 000 987 11 45.
If vacuum is not available at the vacuum distribution block with the PSE
control module operating correctly, check the effected lines for clogging
or kinks.
Parts Required for Test:
1 Connector 202 805 03 44
1 Rubber hose, 50 mm long 007 997 61 82
1 Pneumatic line, 1m long 000 158 14 35
1 Cap 000 987 11 45
|
|
Test scope |
Test connection |
Test condition |
Nominal value |
Possible cause/Remedy |
2.0 |
Vacuum applied to pneumatic lines
|
Black connector
on tester. |
Apply 300 mbar vacuum to vacuum distribution
block and lines. |
Vacuum loss
0 mbar in
1 minute.
|
Vacuum distributor block leak.
Replace. |
Preparation for Test:
1. Connect tester to pneumatic lines.
Parts Required for Test:
1 Cap 000 987 11 45
1 Rubber hose, 50 mm long 007 997 61 82
1 Connector 202 805 03 44
|
|
Test scope |
Test connection |
Test condition |
Nominal value |
Possible cause/Remedy |
3.0 |
Vacuum leakage |
Black connector
on tester. |
Apply 300 mbar vacuum
to pneumatic lines. |
Vacuum loss
0 mbar in
1 minute.
|
Pneumatic lines.
Repair/Replace. |
|