1. Review 21, 22, 23 (connector connections).
2. Ignition: OFF
3. Disconnect BAS control module (N48).
4. Connect socket box with test cable as per connection
diagram (Figure 1).
Electrical Wiring Diagrams:
(location of grounds and connectors)
Electrical Troubleshooting Manual, Model 129, Group 42 and 00,
Electrical Troubleshooting Manual, Model 140, Group 42 and 00,
Electrical Troubleshooting Manual, Model 170, Group 42 and 00,
Electrical Troubleshooting Manual, Model 202, 208, Group 42 and 00,
Electrical Troubleshooting Manual, Model 210, Group 42 and 00.
|
Test Equipment; See MBUSA Standard Service Equipment Program
Description |
Brand, model, etc. |
Digital multimeter |
Fluke models 23, 77 III, 83, 85, 87 |
Parameterizing BAS control module, model 129
Model
|
Engine
|
Control module parameter:
Teves
025 545 48 32
Lucas
025 545 47 32
|
129 |
104, 112 |
4 |
129 |
113, 119, 120 |
3 |
Parameterizing BAS control module, model 140
Model
|
Engine
|
Control module parameter:
Teves
020 545 16 32
Lucas
023 545 55 32
019 545 32 32 |
Control module parameter:
Teves
025 545 48 32
Lucas
025 545 47 32
|
140 |
119, 120 |
8 |
8 |
140 |
104 |
2 |
2 |
170 |
111 |
10 |
10 |
Parameterizing BAS control module, model 202
Model
|
Engine
|
Control module parameter:
Teves
020 545 16 32
Lucas
023 545 55 32
019 545 32 32 |
Control module parameter:
Teves
025 545 48 32
Lucas
025 545 47 32
|
202 |
104, 111, 112 |
7 |
7 |
Parameterizing BAS control module, model 208
Model
|
Engine
|
Control module parameter:
Teves
020 545 16 32
Lucas
023 545 55 32
019 545 32 32 |
Control module parameter:
Teves
025 545 48 32
Lucas
025 545 47 32
|
208 |
112 |
9 |
9 |
208 |
113 |
1 |
11 |
Parameterizing BAS control module, model 210
Model
|
Engine
|
Control module parameter:
Teves
020 545 16 32
Lucas
023 545 55 32
019 545 32 32 |
Control module parameter:
Teves
025 545 48 32
Lucas
025 545 47 32
|
210 Sedan |
104, 112.941, 113
|
5 |
5 |
210 Sedan |
606 |
5 |
21 |
|