Diagnostic Manual, Body and Accessories,
Volume 1.1
Electrical Test Program - Test
Preparation for Test:
1. Review section 0,
2. Review C/1, 20,
21,
31,
32 |
|
|
Test scope |
Test connection |
Test condition |
Nominal value |
Possible cause/Remedy |
1.0 |
|
Remote trunk release |
|
Trunk lid closed.
Trunk lid not locked with mechanical key.
Remote trunk release switch (N72s15):
Press switch: |
Trunk lid opens.
LED in switch illuminated. |
32 PSE/RTR
1.0,
See AD80.20-P-8000-10B,
PSE (A37),
Lower control field control
module (N72),
Mechanical fault in trunk lid lock,
23 PSE/RTR
3.0 |
2.0 |
|
Trunk release
switch (S15/1) |
|
Trunk lid closed.
Trunk lid not locked with mechanical key.
Unlock trunk lid by pressing lock button on trunk release switch. |
Trunk lid opens.
LED in switch illuminated. |
See AD80.20-P-6000-15B,
32 PSE/RTR
1.0,
See AD80.20-P-8000-10B,
PSE (A37),
Mechanical fault in trunk lid lock,
23 PSE/RTR
3.0 |
3.0 |
|
Trunk lamp switch (S17/8) |
|
Trunk lid unlocked via remote trunk
release switch (N72s15). |
LED in switch (N72s15) illuminated.
|
Wiring,
See AD80.20-P-6000-14B,
S17/8,
Lower control field control
module (N72),
PSE (A37). |
|